ICF-C295 - Sony Audio Service Manual (repair manual). Page 5

Read Sony ICF-C295 Service Manual online

FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
86.5 MHz
CT3
109.5 MHz
FM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
Confirm
86.5 MHz
CT2
109.5 MHz
AM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520 kHz
CT4
1,650 kHz
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
600 kHz
CT1
1,500 kHz
AM  IF  ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455 kHz
– 5 –
SECTION  3
ELECTRICAL  ADJUSTMENTS
FM  SECTION
Setting:
BAND switch: FM
AM  SECTION
Setting:
BAND switch: AM
• Repeat the procedures in each adjustment several times, and
the frequency coverage and tracking adjustments should be fi-
nally done by the trimmer capacitors.
Adjustment Location: MAIN board (Component Side)
FM RF signal 
generator
400 Hz, 30% FM modulation 
frequency deviation 
±
 22.5 kHz   
Output level: as low as possible
0.01 
µ
F
set
MAIN board
(Conductor Side)
TP (RF IN)
AM RF signal 
generator
400 Hz, 30%
AM modulation
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
level meter
set
speaker terminal
+
(RF IN)
IC1
AM FREQUENCY
COVERAGE ADJUSTMENT
CT2
FM TRACKING ADJUSTMENT
AM TRACKING ADJ
T1
AM IF ADJUSTMENT
FM FREQUENCY
COVERAGE ADJUSTMENT
L4     CT4
L3     CT3
CV1
TP
L1
CT1
Page of 9
Display