ICF-C295 - Sony Audio Service Manual (repair manual)

icf-c295 service manual
Model
ICF-C295
Pages
9
Size
205.09 KB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
icf-c295.pdf
Date

Read Sony ICF-C295 Service Manual online

FM/AM CLOCK RADIO
MICROFILM
US Model
Canadian Model
SPECIFICATIONS
SERVICE MANUAL
ICF-C295
– 2 –
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
!
  OR  DOTTED
LINE  WITH  MARK  
!
  ON  THE  SCHEMATIC  DIAGRAMS
AND  IN  THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE
OPERATION.  REPLACE  THESE  COMPONENTS  WITH
SONY  PARTS  WHOSE  PART  NUMBERS  APPEAR  AS
SHOWN  IN  THIS  MANUAL  OR  IN  SUPPLEMENTS  PUB-
LISHED  BY  SONY.
CF2
CF3
mark
Mark
Center frequency
red
10.70 MHz
blue
10.67 MHz
orange
10.73 MHz
black
10.64 MHz
white
10.76 MHz
HOW TO CHANGED THE CERAMIC FILTERS
This model is used two ceramic filters of CF2 and CF3.
You must used same type of color marked ceramic filters in order
to meet same specifications.
Therefore, the ceramic filter must changed two pieces together
since it's supply two pieces in one package as a spare parts.
ATTENTION  AU  COMPOSANT  AYANT  RAPPORT
À  LA  SÉCURITÉ!
LES  COMPOSANTS  IDENTIFIÉS  PAR  UNE  MARQUE  
!
SUR  LES  DIAGRAMMES  SCHÉMATIQUES  ET  LA  LISTE
DES  PIÈCES  SONT  CRITIQUES  POUR  LA  SÉCURITÉ
DE  FONCTIONNEMENT.  NE  REMPLACER  CES  COM-
POSANTS  QUE  PAR  DES  PIÈCES  SONY  DONT  LES
NUMÉROS  SONT  DONNÉS  DANS  CE  MANUEL  OU
DANS  LES  SUPPLÉMENTS  PUBLIÉS  PAR  SONY.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The “limit” indication is 0.75
V, so analog meters must have an accurate low-voltage scale.
The Simpson 250 and Sanwa SH-63Trd are examples of a pas-
sive VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2 V AC range are suitable.  (See Fig. A)
Fig. A.
Using an AC voltmeter to check AC leakage.
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
– 3 –
SECTION  1
GENERAL
This section is extracted from
instruction manual.
– 4 –
7
claws
5
MAIN board
3
Turn shaft of CV1 to the 
arrow 
A
 direction fully.
4
Turn RV1 to the arrow 
B
 
direction fully.
6
claw
2
Turn the knob (VOL) to the 
arrow 
B
 direction fully.
1
Turn the knob (tuning) to the 
arrow 
A
 direction fully.
A
B
lower cabinet
power cord
Set the power cord as illustrated below, then install the lower cabinet.
SETTING  THE  POWER  CORD
SECTION  2
SETTING
KNOB  SETTING
Page of 9
Display

Download Sony ICF-C295 Service Manual (Repair Manual)

Here you can read online and download Sony ICF-C295 Service Manual in PDF. ICF-C295 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony ICF-C295 Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.