4-15. BATT
LIFE
Not used for the servicing.
4-16. WRITER
VER
Not used for the servicing.
4-17. CHG
LOG
The charge log saved at SRAM can be copied to eMMC.
Procedure:
1. Enter the test mode.
1. Enter the test mode.
(Refer to “SETTING THE TEST MODE” on page 15)
2. Press
the
[
>
] or [
.
] keys to select the “CHG LOG”, and
press the [
N
] key.
3. The charge log saved at SRAM is copied to eMMC.
LCD Display
<CHG LOG>
Success
Releasing method:
Press the [STOP/
Press the [STOP/
x
] key, return to test mode menu.
4-18. LREC
LOG
Not used for the servicing.
4-19. LREC LOG Clear
Not used for the servicing.
Not used for the servicing.
4-20. POWER
OFF
It changes in the power supply off state.
Procedure:
1. Enter the test mode.
1. Enter the test mode.
(Refer to “SETTING THE TEST MODE” on page 15)
2. Press
the
[
>
] or [
.
] keys to select the “POWER_OFF”,
and press the [
N
] key.
3. The power off state selection screen is displayed.
This unit shifts to the power off state by pressing the [
N
] key
again.
LCD Display
<POWER_OFF>
POWER_OFF
POWER_OFF
4. It changes in the power supply off state, and release the test
mode.
4-21. MENU
INIT
This unit can return to the factory shipment settings.
Procedure:
1. Enter the test mode.
1. Enter the test mode.
(Refer to “SETTING THE TEST MODE” on page 15)
2. Press the [
>
] or [
.
] keys to select the “MENU INIT”, and
press the [
N
] key.
3. Initialization is performed.
LCD Display
<MENU INIT>
Formatting...
4. “Success” is displayed, and this unit reboots.
LCD Display
Success
Click on the first or last page to see other ICD-UX543 / ICD-UX543F / ICD-UX544F service manuals if exist.