ICD-UX543, ICD-UX543F, ICD-UX544F - Sony Audio Service Manual (repair manual). Page 21

Read Sony ICD-UX543 / ICD-UX543F / ICD-UX544F Service Manual online

ICD-UX543/UX543F/UX544F
21
4-15. BATT 
LIFE
Not used for the servicing.
4-16. WRITER 
VER
Not used for the servicing.
4-17. CHG 
LOG
The charge log saved at SRAM can be copied to eMMC.
Procedure:
1.  Enter the test mode.
 
(Refer to “SETTING THE TEST MODE” on page 15)
2. Press 
the 
[
>
] or [
.
] keys to select the “CHG LOG”, and 
press the [
N
] key.
3.  The charge log saved at SRAM is copied to eMMC.
LCD Display
<CHG LOG>
Success
Releasing method:
Press the [STOP/
x
] key, return to test mode menu.
4-18. LREC 
LOG
Not used for the servicing.
4-19.  LREC LOG Clear
Not used for the servicing.
4-20. POWER 
OFF
It changes in the power supply off state.
Procedure:
1.  Enter the test mode.
 
(Refer to “SETTING THE TEST MODE” on page 15)
2. Press 
the 
[
>
] or [
.
] keys to select the “POWER_OFF”, 
and press the [
N
] key.
3.  The power off state selection screen is displayed.
 
This unit shifts to the power off state by pressing the [
N
] key 
again.
LCD Display
<POWER_OFF>
POWER_OFF
4.  It changes in the power supply off state, and release the test 
mode.
4-21. MENU 
INIT
This unit can return to the factory shipment settings.
Procedure:
1.  Enter the test mode.
 
(Refer to “SETTING THE TEST MODE” on page 15)
2.  Press the [
>
] or [
.
] keys to select the “MENU INIT”, and 
press the [
N
] key.
3.  Initialization is performed.
LCD Display
<MENU INIT>
Formatting...
4.  “Success” is displayed, and this unit reboots.
LCD Display
Success