Read Sony ICD-UX532 / ICD-UX533 / ICD-UX533F / ICD-UX534F Service Manual online
ICD-UX532/UX533/UX533F/UX534F
4
3. Confi rmation method
Procedure:
1. Equip this unit with battery.
2. Slide the [HOLD•POWER] switch in the direction of “POW-
Procedure:
1. Equip this unit with battery.
2. Slide the [HOLD•POWER] switch in the direction of “POW-
ER” until the window display appears.
HOLD
POWER
3. Slide the [DPC (SPEED CTRL)] switch to OFF.
DPC (SPEED CTRL) OFF
ON
4. While pressing the [STOP/
x
] and [VOL –] keys, slide the
[DPC (SPEED CTRL)] switch to ON.
DPC (SPEED CTRL) OFF
ON
STOP/x
VOL –
5. The test mode menu is displayed, and enter the test mode. Re-
lease the [STOP/
x
] and [VOL –] keys.
6. Confi rm that the destination has been changed.
(Displayed characters/values in the following fi gure are ex-
ample)
ample)
<SERVICE MENU>
ICD-UX532/CN
1.00.01
1.00.01
Destination
Model name
Firmware version
Model name
Firmware version
LCD Display
7. Remove battery to release the test mode.
(Test mode is released by removing the battery)
ABOUT THE DESTINATION SETTING WHEN REPLAC-
ING THE MAIN BOARD
When the MAIN board of this unit is replaced, perform processing
according to the following procedure.
ING THE MAIN BOARD
When the MAIN board of this unit is replaced, perform processing
according to the following procedure.
Precaution
The contents which are not opened to customers are included
in the following procedure. After you are cautious of handling of
information, execute work under the suffi cient administration.
The contents which are not opened to customers are included
in the following procedure. After you are cautious of handling of
information, execute work under the suffi cient administration.
1. About the preparing of tools
Download the tools used by this work from the homepage of TISS.
When the tools cannot be confi rmed by TISS, confi rm to the ser-
vice headquarters.
Download the tools used by this work from the homepage of TISS.
When the tools cannot be confi rmed by TISS, confi rm to the ser-
vice headquarters.
2. Setting
method
Note: The destination setting is impossible when battery voltage is not
enough.
Do work using the battery with suffi cient battery level.
Procedure:
1. Equip this unit with battery.
2. Connect this unit to the PC.
1. Equip this unit with battery.
2. Connect this unit to the PC.
PC
IC recorder
To USB port of PC
3. On PC, unzip the model setting fi le to get folder on PC.
4. On PC, open the unzipped folder, and select the folder corre-
4. On PC, open the unzipped folder, and select the folder corre-
sponding to the model name and destination of this unit.
01.ICD-UX533_U
02.ICD-UX532_CE7
03.ICD-UX533_CE7
04.ICD-UX534F_CE7
05.ICD-UX533F_LA
06.ICD-UX533_CA
07.ICD-UX532_J
08.ICD-UX533F_J
02.ICD-UX532_CE7
03.ICD-UX533_CE7
04.ICD-UX534F_CE7
05.ICD-UX533F_LA
06.ICD-UX533_CA
07.ICD-UX532_J
08.ICD-UX533F_J
09.ICD-UX534F_J
10.ICD-UX532_CN
11.ICD-UX533F_CN
12.ICD-UX534F_CN
13.ICD-UX533F_KR3
14.ICD-UX533F_E
15.ICD-UX534F_E
10.ICD-UX532_CN
11.ICD-UX533F_CN
12.ICD-UX534F_CN
13.ICD-UX533F_KR3
14.ICD-UX533F_E
15.ICD-UX534F_E
5. On PC, copy the “DEVINFO.UPG” fi le included in the folder
selected at step 4 to root folder of this unit.
6. Remove this unit from the PC.
PC
IC recorder
From USB port of PC
7. “Updating” is displayed on the screen of this unit, and this unit
is rebooted automatically.
Updating...
LCD Display
8. The destination setting is completed.