Read Sony ICD-UX200 / ICD-UX200F / ICD-UX300 / ICD-UX300F / ICD-UX400F Service Manual online
ICD-UX200/UX200F/UX300/UX300F/UX400F
9
[PLAY]: Loop Back Start
[VOL+], [VOL–]: Volume operation to set. (Initial value 20)
[DPC]: OFF: Sensitivity H, ON: Sensitivity L
[HOLD ON]: (ON: High sensitivity SH)
[A-B]: External mic select (MIC IN t AUDIO IN)
[VOL+], [VOL–]: Volume operation to set. (Initial value 20)
[DPC]: OFF: Sensitivity H, ON: Sensitivity L
[HOLD ON]: (ON: High sensitivity SH)
[A-B]: External mic select (MIC IN t AUDIO IN)
[REC]: AGC ON/OFF select (AGC ON y AGC OFF)
4. SetMic Cal
Write the correction value for the level difference between L and R
channels of the internal stereo microphone into the eMMC NAND
memory. With the L channel level as the reference, measure the R
channel recording level. Then adjust the R channel’s ADC VOL
level so that the R channel level is equal to the L channel level.
* Make a mental note of the setting even when the battery has been
Write the correction value for the level difference between L and R
channels of the internal stereo microphone into the eMMC NAND
memory. With the L channel level as the reference, measure the R
channel recording level. Then adjust the R channel’s ADC VOL
level so that the R channel level is equal to the L channel level.
* Make a mental note of the setting even when the battery has been
removed.
[PLAY]: Recording start
5. Beep
Test to Beep.
Test to Beep.
[PLAY]: 800 Hz t 1.3 kHz t 2.0 kHz t 800 Hz ......
[STOP]: STOP
6. LCD Cont
Adjust the LCD contrast.
* Make a mental note of the setting even when the battery has been
Adjust the LCD contrast.
* Make a mental note of the setting even when the battery has been
removed.
Initial value: 46
[FF]: +
[FR]: –
[FF]: +
[FR]: –
7. RTC Int
Perform a self- test on RTC.
Perform a self- test on RTC.
The count is indicated every second.
8. Battery
Check the current value of Battery A/D.
Check the current value of Battery A/D.
9. Batt AB4
Check the current value of Battery x4A/D.
Check the current value of Battery x4A/D.
10. VBUS TEST
Check the presence of VBUS.
Check the presence of VBUS.
[PLAY]: Suspend, LCD off
To reset, remove the battery and then insert it again.
To reset, remove the battery and then insert it again.
11. MENU INIT
Initialize the set values.
Initialize the set values.
[PLAY]: Menu initialize start.
12. Sleep
Perform a sleep test.
The LCD display disappears and then the sleep mode is entered.
To exit the sleep mode, turn off power.
The power should be turned on again since resetting is not allowed.
Perform a sleep test.
The LCD display disappears and then the sleep mode is entered.
To exit the sleep mode, turn off power.
The power should be turned on again since resetting is not allowed.
LCD display
<SetMIC Cal>
R-ch: –02dB
LCD display
<LCD Cont>
Value: 46
[FF] + [FR] -
LCD display
<RTC lnt>
01s
RTC lnt OK
LCD display
<Battery>
XxXX
LCD display
<Batt4>
XxXX
LCD display
<Menu lnit>
[PLAY]: ENTER
LCD display
<VBUS Test>
VBUS OFF
Click on the first or last page to see other ICD-UX200 / ICD-UX200F / ICD-UX300 / ICD-UX300F / ICD-UX400F service manuals if exist.