ICD-S7 - Sony Audio Service Manual (repair manual). Page 8

Read Sony ICD-S7 Service Manual online

8
ICD-S7
SECTION 3
TEST MODE
[Setting Method of the Test Mode]
There are two different methods to enter the test mode:
(1) To enter the test mode, turn on the HOLD switch while pressing
the STOP key and VOLUME+ key at the same time with the
power on.
(2) While pressing the VOLUME- key, turn on the power in state
that the test land (TP7101 (side B) or SL7101 (side A)) on the
main board is shorted to GND.
[Exiting Method of the Test Mode]
Exit the test mode by turning off the power.
[Initial Status of the Test Mode]
When the test mode is set, the LCD display appears as shown below.
LCD display
102 3C 01 J
Destination information
LPEC version
DSP version
CPU version
102  3C  01  J
LCD TEST
.
>
SET AREA
.
>
AUDIO TEST
.
>
SLEEP TEST
.
>
BEEP TEST
.
>
SIO TEST
.
>
KEY TEST
.
>
.
>
RESET MENU
>
.
READ DATA
>
.
DC JACK
>
.
USB TEST
>
.
LED TEST
>
.
BATT TEST
>
.
Initial status of test mode
Version display
Destination setting information display
END
TEST MODE
START
TEST MODE
[Operation in the Test Mode]
After entering the test mode, you can move within the test menu by
pressing the .  /  >  key. You can move to the submenu by
pressing the x
•B key. Then each test mode can be executed.
1. LCD test
• LCD is tested of all light-on and all light-off.
• Use the . / > key to adjust the contrast of the LCD. The
setting value is written in the EEPROM with the x
•B key. If the
LCD test ends with OK, “**** OK ****” is displayed. If the
LCD test ends with NG, “****NG****” is displayed.
The default value is “0x12”.
x•B
LCD TEST
LCD ALL
LCD OFF
LCD CHECK
LCD ALL
LCD CHECK
:
:
STOP
STOP
STOP
STOP
(select), (set) 
.
>
x•B
LCD OFF
2. Setting destination
•  NO destination information.
3. Audio test
Perform the through-playback and sine wave output.
• Contents of the submenu
ADA SP: AD/DA-through-SP mode
ADA LP: AD/DA-through-LP mode
DSP SP: DSP-through-SP mode
DSP LP: DSP-through-LP mode
1 kHz SIN: 1 kHz sine wave output mode
• Select the microphone sensitivity with the  HOLD  switch.
ON: High sensitivity
OFF: Low sensitivity
• The VOR detection operation can be checked by the LED.
Sound: The red LED is turned on. No sound: The red LED is
turned off.
• MUTE can be set to “ON” or “OFF” with the  ERASE  key.
• The sound volume can be adjusted with the  VOLUME+  key or
 VOLUME-  key during the audio test except the MUTE mode.
• The microphone sensitivity, sound volume and MUTE (on/off)
are displayed on the bottom of the LCD.
x•B
SET AREA
JAPAN USB
STOP
x•B
:
:
DSP SP
ADA LP
ADA SP
1K SIN
DSP LP
AUDIO TEST
DSP LP
DSP LP H 10
DSP SP H 10
ADA LP H 10
(select), (set) 
.
>
x•B
STOP
STOP
STOP
STOP
[Flow Chart of the Test Mode]
Page of 37