11
Precaution
1.
Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads
pinch rollers
erase head
rubber belts
capstan
idlers
2.
Demagnetize the record/playback head with a head
demagnetizer.
3.
Do not use a magnetized screwdriver for the adjustments.
4.
After the adjustments, apply suitable locking compound to the
parts adjusted.
5.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
Torque Measurement
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
100 g or more
(3.53 oz or more)
100 g or more
(3.53 oz or more)
7.
Switches and controls should be set as follows unless otherwise
specified.
Record/Playback Head Azimuth Adjustment
(Deck A, Deck B)
Note: Perform this adjustments for both decks.
Procedure:
1.
Mode : Playback
SECTION 4
MECHANICAL ADJUSTMENTS
Mode
FWD
FWD
back tension
REV
REV
back tension
FF/REW
FWD tension
REV tension
Torque meter
CQ-102C
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
Meter reading
SECTION 5
ELECTRICAL ADJUSTMENTS
Read before adjustments
To adjust the unit, operate the unit by itself using the conduction jig
(PFJ-1).
For details on switching functions and fast forwarding the unit, etc.
when operating it by itself, refer to “Connection and Operations of
the Unit by Itself” on page 5 of Servicing Notes.
• Turning on the power
When operating the unit by itself:
1.
After turning ON the power of the conduction tool (PFJ-1),
press the  
π (TAPE A)  button,  π (TAPE B)  button, and  ·
(TAPE B)  button together in this order.
Inputting/outputting audio signals:
Use the jack of the power supply jig (PFJ-1).
P-4-A100
WS-48B
P-4-L300
10 kHz, –10 dB
3 kHz, 0 dB
315 Hz, 0 dB
PFJ-1
Output point
Input point
DECK SECTION
0 dB=0.775V
1.
Demagnetize the record/playback head with a head
demagnetizer.
2.
Do not use a magnetized screwdriver for the adjustments.
3.
After the adjustments, apply suitable locking compound to the
parts adjusted.
4.
The adjustments should be performed with the rated power
supply voltage unless otherwise noted.
5.
The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit
adjustment.)
6.
The adjustments should be performed for both L-CH and R-
CH.
set
test tape
P-4-A100
(10kHz, -10dB)
PFJ-1
level meter
output point
Signal
Used for
Tape
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
Page of 53
Display