HCD-GS200, MHC-GS200 - Sony Audio Service Manual (repair manual). Page 21

Read Sony HCD-GS200 / MHC-GS200 Service Manual online

21
HCD-GS200
CD  SECTION
Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10M
 impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S-curve Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (FE1) and TP (DVC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in and turned power switch on again
and actuate the focus search. (actuate the focus search when
disc table is moving in and out)
4.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2 
±
 1
Vp-p.
S-curve waveform
Note:
• Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: CD board (Conductor side)
(See page 22.)
+
CD board
TP (FE1)
TP (DVC)
oscilloscope
A
B
symmetry
within 2 
±
 1 Vp-p
RFAC Level Check
Connection:
Procedure:
1.
Connect an oscilloscope to test point TP (RFAC) and TP (DVC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (YEDS-18) in to playback the number five track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note:
A clear RFAC signal waveform means that the shape “
” can be
clearly distinguished at the center of the waveform.
       RFAC signal waveform
Checking Location: CD board (Conductor side)
(See page 22.)
+
CD board
TP (RFAC)
TP (DVC)
oscilloscope
VOLT/DIV: 200 mV
TIME/DIV: 500 ns 
level: 1.35 
±
 0.4 Vp-p
Page of 64
Display