Read Sony HCD-GRX10AV / HCD-RX110AV / MHC-GRX10AV / MHC-RX110AV (serv.man2) Service Manual online
– 14 –
Precaution
1. Clean the following parts with a denatured alcohol-moistened
swab:
record/playback heads pinch rollers
erase head rubber belts
capstan idlers
erase head rubber belts
capstan idlers
2. Demagnetize the record/playback head with a head demagne-
tizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
Torque Measurement
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
31 to 71 g • cm
(0.43 – 0.98 oz • inch)
2 to 6 g • cm
(0.02 – 0.08 oz • inch)
71 to 143 g • cm
(0.98 – 1.99 oz • inch)
100 g or more
(3.53 oz or more)
100 g or more
(3.53 oz or more)
Record/Playback Head Azimuth Adjustment
(Deck A, Deck B)
(Deck A, Deck B)
Note: Perform this adjustments for both decks.
Procedure:
1. Mode : Playback
1. Mode : Playback
Signal
Used for
Tape
SECTION 5
MECHANICAL ADJUSTMENTS
Mode
FWD
Torque meter
CQ-102C
Meter reading
FWD
back tension
back tension
REV
REV
back tension
back tension
FF/REW
FWD tension
REV tension
CQ-102C
CQ-102RC
CQ-102RC
CQ-201B
CQ-403A
CQ-403R
SECTION 6
ELECTRICAL ADJUSTMENTS
DECK SECTION 0 dB=0.775V
1. Demagnetize the record/playback head with a head damagnetizer.
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
2. Do not use a magnetized screwdriver for the adjustments.
3. After the adjustments, apply suitable locking compound to the
parts adjusted.
4. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
5. The adjustments should be performed in the order given in this
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit adjust-
ment.)
should be completed before performing recording circuit adjust-
ment.)
6. The adjustments should be performed for both L-CH and R-CH.
7. Switches and controls should be set as follows unless otherwise
7. Switches and controls should be set as follows unless otherwise
specified.
P-4-A100
WS-48B
P-4-L300
10 kHz, –10 dB
3 kHz, 0 dB
315 Hz, 0 dB
Azimuth Adjustment
Tape Speed Adjustment
Level Adjustment
2. Turn the adjustment screw and check output peaks. If the peaks
do not match for L-CH and R-CH, turn the adjustment screw so
that outputs match within 1 dB of peak.
that outputs match within 1 dB of peak.
L-CH
peak
peak
R-CH
peak
peak
screw
position
position
output
level
level
within
1 dB
1 dB
L-CH
peak
peak
R-CH
peak
peak
screw
position
position
within 1dB
test tape
P-4-A100
(10kHz, –10dB)
P-4-A100
(10kHz, –10dB)
main board
CN301
Pin
CN301
Pin
1
(L-CH)
Pin
3
(R-CH)
level meter
set
+
–
main board
CN301
Pin
CN301
Pin
2
(GND)
Click on the first or last page to see other HCD-GRX10AV / HCD-RX110AV / MHC-GRX10AV / MHC-RX110AV (serv.man2) service manuals if exist.