Read Sony HCD-GN1200D / MHC-GN1200D Service Manual online
HCD-GN1200D
20
Protection VACS) and “C” represent APVACS level which is
triggered.
triggered.
[DVD SERVICE MODE]
• This mode let you make diagnosis and adjustment easily by
• This mode let you make diagnosis and adjustment easily by
using the remote commander and TV. The instructions, diag-
nostic results, etc. are given on the on-screen display (OSD).
nostic results, etc. are given on the on-screen display (OSD).
Procedure:
1. Press
1. Press
button to turn on the system.
2. Select DVD function.
3. Press
3. Press
Y
button and [OPEN/CLOSE] button simultaneously
and then turn [MASTER VOLUME] knob clockwise.
4. The message “SERVICE IN” appears on the fl uorescent indi-
cator tube and the Top Menu of Remocon Diagnosis Menu ap-
pears on the on-screen display on the TV. The model name and
revision number is displayed at the bottom of the on-screen
display.
pears on the on-screen display on the TV. The model name and
revision number is displayed at the bottom of the on-screen
display.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
Model name : XXXXX-XX
IF-con
: Ver.XX.XX(XXXX)
Syscon : Ver.X.XXX
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press button to turn off the sys-
tem.
[EXECUTE IOP MEASUREMENT]
In order to execute IOP measurement, the following standard
procedures must be followed.
procedures must be followed.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History Check
4. Version information
Model name : XXXXX-XX
IF-con
: Ver.XX.XX(XXXX)
Syscon : Ver.X.XXX
2. Select “2. Drive Manual Operation” by pressing [2] button on
the remote commander. The screen will appear as follows.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mech test mode
5. MIRR time adjust
0. Return to top Menu
3. Select “3. Manual Adjustment” by pressing [3] button on the
remote commander. The screen will appear as follows.
Manual Adjust
1. Track Balance Adjust :
2. Track Gain Adjust :
3. Focus Balance Adjust :
4. Focus Gain Adjust :
5. Eq boost Adjust :
6. Iop :
7. TRV. Level :
8. S curve (FE) Level :
9. RFL(PI) Level :
0. MIRR Time :
Y9Change value
RETURN Return to previous menu
4. Select “6.Iop” by pressing [6] button on the remote
commander.
5. Wait until a hexadecimal number appear as follows.
commander.
5. Wait until a hexadecimal number appear as follows.
Manual Adjust
1. Track Balance Adjust :
2. Track Gain Adjust :
3. Focus Balance Adjust :
4. Focus Gain Adjust :
5. Eq Boost Adjust :
6. Iop :
ED :
7. TRV. Level :
8. S curve (FE) Level :
9. RFL(PI) Level :
0. MIRR Time :
Y9Change value
RETURN Return to previous menu
6. Convert data from hexadecimal to decimal using conversion
table.
7. Please
fi nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
8. Subtract between these two values.
9. If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defec-
tiveand need to be change.
tiveand need to be change.
10. Press
0 RETURN
button on the remote commander to return
to previous menu.
11. Press [0] button on the remote commander to return to the Top
Menu of Remocon Diagnosis Menu.
12. Press
button to turn off the set.
Click on the first or last page to see other HCD-GN1200D / MHC-GN1200D service manuals if exist.