HCD-FX900W
Fix the capacitors with adhesive agent as follows
Fixing the capacitors with adhesive agent is required by the safety regulation. 
Be sure to fix the capacitors with adhesive agent when part or circuit board is replaced. 
POWER BOARD
PRECAUTION WHEN INSTALLING A NEW OP UNIT / 
PRECAUTION BEFORE UNSOLDERING THE STATIC ELECTRICITY 
PREVENTION SOLDER BRIDGE
When installing a new OP unit, be sure to connect the flexible printed circuit board first of all before removing the static 
electricity prevention solder bridge by unsoldering. Remove the static electricity prevention solder bridge by unsoldering 
after the flexible printed circuit board has already been connected. 
(Do not remove nor unsolder the solder bridge as long as the OP unit is kept standalone.)