HCD-FX900W
SECTION  1
SERVICING  NOTE
NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK
OR BASE UNIT
The laser diode in the optical pick-up block may suffer electrostatic
break-down because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The flexible board is easily damaged and should be handled with
care.
DISC SLOT LOCK
The disc slot lock function for the antitheft of an demonstration
disc in the store is equipped.
Setting Procedure :
1. Press the  ?/1  button to turn the set on.
2. Press the [FUNCTION] button to set DVD function.
3. Insert a disc.
4. Press the  
x  
stick and the  
 button simultaneously for five
seconds.
5. The message “LOCKED” is displayed and the slot is locked.
Releasing Procedure :
1. Press the  
x  
stick and the  
 button simultaneously for five
seconds again.
2. The message “UNLOCKED” is displayed and the slot is
unlocked.
Note:
When “LOCKED” is displayed, the slot lock is not released by
turning power on/off with the  ?/1  button.
Note on DMB12 board replacement
New part of EEP ROM (IC103, IC706) on the DMB12 board cannot
be used. Therefore, if the mounted DMB12 board (A-1154-509-A)
is replaced, exchange new EEP ROM (IC103, IC706) with that used
before the replacement.
When the self-diagnosis function is activated to 
prevent the system from malfunctioning, a 5-
character service number (e.g., C 13 50) with a 
combination of a letter and 4 digits appears on 
the screen and the front panel display. In this 
case, check the following table.
When displaying the version 
number on the screen
When you turn on the system, the version 
number [VER.X.XX] (X is a number) may 
appear on the screen. Although this is not a 
malfunction and for Sony service use only, 
normal system operation will not be possible. 
Turn off the system, and then turn on the system 
again to operate.
Self-diagnosis Function 
(When letters/numbers appear in the 
display)
First 3 
characters of 
the service 
number
Cause and/or corrective action
C 13
The disc is dirty.
,Clean the disc with a soft cloth 
C 31
The disc is not inserted correctly.
,Restart the system, then re-insert 
the disc correctly.
E XX
(xx is a number)
To prevent a malfunction, the 
system has performed the self-
diagnosis function.
,Contact your nearest Sony 
dealer or local authorized Sony 
service facility and give the 5-
character service number.
Example: E 61 10
C:13:50
VER.X.XX
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused on
the disc reflective surface by the objective lens in the optical pick-
up block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.