HCD-DX70 - Sony Audio Service Manual (repair manual). Page 19

Read Sony HCD-DX70 Service Manual online

19
HCD-DX70
Note: Clear RF signal waveform means that the shape “
◊” can be
clearly distinguished at the center of the waveform.
RF signal waveform
E-F Balance (1 Track jump) Check
Procedure:
1.
Connect oscilloscope to TP (TEO) and TP (DVC) board.
2.
Turned Power switch on.
3.
Load a disc (LUV-P01) and playback the number nine track.
4.
Press the  bB  button. (Becomes the 1track jump mode.)
5.
Confirm that the level B and A (DC voltage) on the oscilloscope
waveform.
1 track jump waveform
6.
Adjust RV101 so that A (DC voltage) becomes 0.
VOLT/DIV : 200mV
TIME/DIV : 500ns
level : 0.65 
± 0.15Vp-p (RFDC)
1.1 
± 0.4Vp-p (RFAC)
oscilloscope
BD board
TP (TEO)
TP (DVC)
+
DVC
Center of
waveform
B
Symmetry
A (DC voltage)
level=1.0
±0.5Vp-p
Checking Location:
[BD BOARD]
DVC
RFAC
RFDC
FEO
TEO
Page of 71
Display

Click on the first or last page to see other HCD-DX70 service manuals if exist.