HCD-CX5BIP - Sony Audio Service Manual (repair manual). Page 12

Read Sony HCD-CX5BIP Service Manual online

HCD-CX5BiP
12
SECTION  4
ELECTRICAL  CHECK
FM  AUTO  STOP  CHECK
generator
UNIT
+
75 
:
Procedure :
1.  Turn the power on.
2.  Input the following signal from Signal Generator to FM an-
tenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 35 dBu (EMF)
Note: Please use 75 ohm “coaxial cable” to connect SG and the set. You 
cannot use video cable for checking.
 
  Please use SG whose output impedance is 75 ohm. 
 
3.  Set to FM tuner function and scan the input FM signal with 
automatic scanning.
4. Confi rm that input Frequency of A, B and C detected and auto-
matic scanning stops.
 
The stop of automatic scanning means “The station signal is re-
ceived in good condition”.
Page of 54
Display

Click on the first or last page to see other HCD-CX5BIP service manuals if exist.