4
3. Flow When “PROTECT” is Displayed
“PROTECT” is
displayed on the
fluorescent
indicator tube.
displayed on the
fluorescent
indicator tube.
Check that the speakers are connected.
NG
Refer to the “Main board confirmation” on page 2.
After the speakers are disconnected, check that
the “PROTECT” is displayed on the fluorescent
indicator tube.
the “PROTECT” is displayed on the fluorescent
indicator tube.
NG
Check the connection state of the speakers.
OK
OK
Check that voltage (+3.3 V) is outputted from the
pin 2 (OUT) of IC504 on the MAIN board.
pin 2 (OUT) of IC504 on the MAIN board.
NG
Exchange the IC504.
Part No.
9-885-166-90
Part No.
9-885-166-90
Description
IC AZ1117D-3.3
IC AZ1117D-3.3
OK
Check that there is no heat damage in the
appearance of IC101/IC102/IC103 on the
MAIN board.
appearance of IC101/IC102/IC103 on the
MAIN board.
OK
Exchange the MAIN board.
NG
Exchange the IC101/IC102/IC103.
Part No.
9-885-166-88
Part No.
9-885-166-88
Description
IC STA518
IC STA518
4. Flow When “REG ERR” is Displayed
“REG ERR” is
displayed on the
fluorescent
indicator tube.
displayed on the
fluorescent
indicator tube.
Exchange the MAIN board.
5. Flow When “LOCKED” is Displayed
“LOCKED” is
displayed on the
fluorescent
indicator tube when
the EJECT button
on main unit.
displayed on the
fluorescent
indicator tube when
the EJECT button
on main unit.
Press the EJECT and STOP button on main unit
five seconds or more simultaneously.
five seconds or more simultaneously.
Check that “UNLOCKED” is displayed on the
fluorescent indicator tube, after “PLEASE WAIT”
is displayed.
fluorescent indicator tube, after “PLEASE WAIT”
is displayed.
NG
OK
Press the EJECT button on main unit, and check
that the display on the fluorescent indicator tube
is disappeared.
that the display on the fluorescent indicator tube
is disappeared.
NG
Exchange the MAIN board.
OK
End