– 15 –
5.
TEMPERATURE COMPENSATION OFFSET
ADJUSTMENT
ADJUSTMENT
Save the temperature data at that time in the non-volatile memory
as 25°C reference data.
as 25°C reference data.
Notes:
1.
Usually, do not perform this adjustment.
2.
Perform this adjustment in an ambient temperature of 22 °C to 28 °C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22
°C to 28 °C.
Perform it immediately after the power is turned on when the internal
temperature of the unit is the same as the ambient temperature of 22
°C to 28 °C.
3.
When D101 has been replaced, perform this adjustment after the tem-
perature of this part has become the ambient temperature.
perature of this part has become the ambient temperature.
Adjusting Method:
1. Turn the
1. Turn the
[
=
SELECTOR
+
]
dial and display “TEMP
ADJUST”.
2. Press the
[ENTER/YES]
button and select the “TEMP AD-
JUST” mode.
3. “TEMP =
” and the current temperature a data will be dis-
played.
4. To save the data, press the
[ENTER/YES]
button.
When not saving the data, press the
[MENU/NO]
button.
5. When the
[ENTER/YES]
button is pressed, “TEMP =
SAVE” will be displayed for some time, followed by “TEMP
ADJUST”.
When the
ADJUST”.
When the
[MENU/NO]
button is pressed, “TEMP ADJUST”
will be displayed immediately.
Specifications:
The temperature should be within “E0-EF”, “F0-FF”, “00-0F”,
“10-1F” and “20-2F”.
The temperature should be within “E0-EF”, “F0-FF”, “00-0F”,
“10-1F” and “20-2F”.
6.
LASER POWER ADJUSTMENT
Preparation:
Referring to “3. Disassembly”, remove the Base Unit from MD
Mechanism Deck.
Referring to “3. Disassembly”, remove the Base Unit from MD
Mechanism Deck.
Connection:
Adjusting Method:
1. Set the laser power meter on the objective lens of the optical
1. Set the laser power meter on the objective lens of the optical
pick-up. (When it cannot be set properly, press the
) button
or
0 button and move the optical pick-up.)
Connect the digital voltmeter to TP29 (IOP+) and TP30
(IOP–) of the BD board.
(IOP–) of the BD board.
2. Turn the
[
=
SELECTOR
+
]
dial and display “LDPWR
ADJUST”.
(Laser power: for adjustment)
(Laser power: for adjustment)
3. Press the
[ENTER/YES]
button and display “LD 0.9 mW $
”.
4. Turn the
[
=
SELECTOR
+
]
dial so that the reading
of the laser power meter becomes 0.82 to 0.93 mW.
Set the range control on the laser power meter to 10 mW, then
press the
Set the range control on the laser power meter to 10 mW, then
press the
[ENTER/YES]
button to save the adjustment result
in the non- volatile memory.
(“LD SAVE $
(“LD SAVE $
” will be displayed for a moment.)
5. Then “LD 7.0 mW $
”will be displayed.
6. Turn the
[
=
SELECTOR
+
]
dial so that the reading
of the laser power meter becomes 6.9 to 7.1 mW, press the
[ENTER/YES]
button and save the adjustment result in the
nonvolatile memory.
(“LD SAVE $
(“LD SAVE $
” will be displayed for a moment.)
Note:
Do not perform the emission with 7.0 mW more than 15 seconds
continuously.
7. Turn the
[
=
SELECTOR
+
]
dial and display “LDPWR
CHECK”.
8. Press the
[ENTER/YES]
button and display “LD 0.9 mW $
”. Check that the reading of the laser power meter becomes
0.80 to 0.96 mW.
9. Press the
[ENTER/YES]
button and display “LD 7.0 mW $
”. Check that the reading of the laser power meter and digi-
tal voltmeter satisfy the specified value.
Specification:
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value
Laser power meter reading : 7.0 ± 0.2 mW
Digital voltmeter reading : Optical pick-up displayed value
±10%
10. Press the
[MENU/NO]
button and display “LDPWR CHECK”,
and stop the laser emission.
(The
(The
[MENU/NO]
button is effective at all times to stop the
laser emission.)
Optical pick-up
objective lens
laser
power meter
power meter
+
–
–
BD board
digital voltmeter
TP29 (IOP +)
TP30 (IOP –)
TP30 (IOP –)
KMS260A
27X40
B0567
B0567
lOP=56.7 mA in this case
lOP (mA) = Digital voltmeter reading (mV)/1 (
lOP (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
(Optical pick-up label)
Click on the first or last page to see other DHC-EX880MD / DHC-MD717 / MDS-EX880 / MDS-MS717 service manuals if exist.