MAIN  BOARD  IC762  TAS3108DCPR (AUDIO  DSP)
Pin No.
Pin Name
I/O
Description
1
AVSS
-
Ground terminal (analog system)
2
VR_PLL
-
External capacitor connection terminal for internal regulator
3
XTALI
I
System clock input terminal (12.288 MHz)
4
XTALO
O
System clock output terminal (12.288 MHz)
5
MCLKI
I
Master clock signal input terminal    Not used
6
MCRCK_DV
I
Internal microprocessor clock divide control signal input terminal    Not used
7
CS0
I
Chip select signal input terminal    Not used
8
GPIO
O
Interrupt signal output to the system controller
9
DVDD
-
Power supply terminal (+3.3V) (digital system)
10
DVSS
-
Ground terminal (digital system)
11
SDIN1
I
Audio data input from the sample rate converter
12, 13
SDIN2, SDIN3
I
Serial data input terminal    Not used
14
SDIN4
I
Muting on/off control signal input from the system controller    “H”: muting on
15
SDA1
I
I2C data input from the system controller
16
SCL1
I
I2C clock signal input from the system controller
17
SDA2
I/O
I2C data bus terminal    Not used
18
SCL2
I/O
I2C clock signal bus terminal    Not used
19
LRCK
I
L/R sampling clock signal input from the sample rate converter
20
SCLKIN
I
Bit clock signal input terminal    Not used
21
MCLKO
O
Master clock signal output to the digital power amplifi er and sample rate converter
22
SCLKOUT1
I
Bit clock signal input from the sample rate converter
23
SCLKOUT2
O
Bit clock signal output to the digital power amplifi er
24 to 26
SDOUT4 to SDOUT2
O
Serial data output terminal    Not used
27
SDOUT1
O
Audio data output to the digital power amplifi er
28
VR_DIG
-
External capacitor connection terminal for internal regulator
29
DVSS
-
Ground terminal (digital system)
30
DVDD
-
Power supply terminal (+3.3V) (digital system)
31
PDN
I
Power down signal input terminal    “L”: power down    Fixed at “H” in this unit
32
RESET
I
Reset signal input from the system controller    “L”: reset
33
RSRV
-
Connected to the ground
34 to 36
PLL0 to PLL2
I
PLL control signal input terminal    Not used
37
RSRV
-
Connected to the ground
38
AVDD
-
Power supply terminal (+3.3V) (analog system)