CMT-HPR95, HCD-HPR95 - Sony Audio Service Manual (repair manual). Page 13

Read Sony CMT-HPR95 / HCD-HPR95 Service Manual online

HCD-HPR95
13
13
HCD-HPR95
Checking Location:
+
CD board
TP (RFACI)
TP (VC)
oscilloscope
(DC range)
Procedure :
1. Connect oscilloscope to TP (RFACI) and TP (VC) on the CD
board.
2. Press the
I/1
button to turn the power on, and press
the
Z
button to open the CD disc table.
3. Set disc (YEDS-18) on the tray and press the
CD u
button
to playback.
4. Confirm that oscilloscope waveform is as shown in the figure
below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
0.9 
±
 0.4 Vp-p
TP
(VC)
TP
(RFACI)
IC201
– CD Board (Conductor Side) –
CD  SECTION
Note:
1.
CD Block is basically constructed to operate without adjustment.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise indicated.
3.
Use an oscilloscope with more than 10 M
Ω impedance.
4.
Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
5.
Check the focus bias check when optical pick-up block is replaced.
FOCUS  BIAS  CHECK
SECTION  5
ELECTRICAL  CHECK
TUNER  SECTION
FM  TUNE  LEVEL  CHECK
Procedure:
1. Turn on the set.
2. Input the following signal from signal generator to FM antenna
input directly.
Carrier frequency: A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
: 75 kHz
Modulation
: 1 kHz
ANT input
: 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and the set.
You cannot use video cable for checking.
Use signal generator whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confirm “TUNED” is lit on the display for A, B and C signals.
When the selected station signal is received in good condition,
“TUNED” is displayed.
signal 
generator
set
Page of 60