CMT-DH30, HCD-DH30 - Sony Audio Service Manual (repair manual). Page 14

Read Sony CMT-DH30 / HCD-DH30 Service Manual online

HCD-DH30
14
1.  DVD  SERVICE  MODE  GENERAL  DESCRIPTION
This mode let you make diagnosis and adjustment easily by using 
the remote commander and the TV screen. The instructions, diag-
nostic results, etc. are given on the on-screen display.
2.  ENTERING  DVD  SERVICE  MODE
Procedure:
1.  Press the [
?/1
] button to turn on the system.
2.  Press the [DVD 
N
] button to select the “DVD”.
3.  Press three buttons of [
x
], [VOLUME +] and [PROGRESSIVE] 
simultaneously.
4.  The message “SERVICE IN” appears on the fl uorescent  in-
dicator tube and top menu of the Remocon Diagnosis Menu 
appears on the on-screen display on the TV screen as follows. 
The model name, IF-con version and Syscon version are dis-
played at the bottom of the on-screen display.
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name 
:DH_xx
IF-con:Ver.xx.xx(xxxx)
Syscon:Ver.x.xxx
5.  To execute each function, press its number by using numeric 
button on the remote commander.
6.  To release from this mode, press the [
?/1
] button to turn off 
the system.
3.  EXECUTING  IOP  MEASUREMENT
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
Procedure:
1.  From the top menu of Remocon Diagnosis Menu, select “2 
Drive Manual Operation” by pressing the [2] button on the 
remote commander. The following screen appears on the on-
screen display
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
2.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The following screen appears on the 
on-screen display.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[
V][v]  Change Value
[RETURN]Return to previous menu
3.  Select “6. Iop:” by pressing [6] button on the remote com-
mander.
4.  Wait until a hexadecimal number appear in the on-screen dis-
play as below.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq boost Adjust:
6. Iop: 57
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[
V][v] Change Value
[RETURN]Return to previous menu
5.  Convert data from hexadecimal to decimal by using conver-
sion table.
6.  If the value is smaller than 93 (decimal), then it is OK. How-
ever if the value is higher than 93, then BU (base unit) is defec-
tive and need to be change.
7.  Press the [
O
 RETURN] button on the remote commander to 
return to previous menu.
8.  Press the [0] button on the remote commander to return to the 
top menu of Remocon Diagnosis Menu.
9.  Press the [
?/1
] button to turn off the system.
DVD  SECTION
Page of 90
Display