CFS-1055L - Sony Audio Service Manual (repair manual). Page 8

Read Sony CFS-1055L Service Manual online

– 8 –
 TUNER SECTION
r
Switch location
FUNCTION switch
• • • • • • • • • • • • • • • • 
RADIO
GRAPHIC EQUALIZER
• • • • • • • • • 
center click
BALANCE
• • • • • • • • • • • • • • • • • • • • • • • • • 
center click
VOLUME
• • • • • • • • • • • • • • • • • • • • • • • • • • • 
mechanical center
BASS BOOST
• • • • • • • • • • • • • • • • • • • • • 
center click
 MW/LW Section
Procedure :
BAND switch
: MW (LW)
FINE TUNING control : mechanical center
                  
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
 SW Section
Procedure :
BAND switch
: SW
FINE TUNING control : mechanical center
                 
AM RF signal
generator
telescopic
antenna
terminal
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
12PF
 FM Section
Procedure :
BAND switch
: FM
FINE TUNEING control : mechanical center
                
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01  F
µ
                
set
32
level meter
phone jack
+
r
Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally done
by the trimmer capacitors.
AM IF ALIGNMENT
Adjust for a maximum reading on level meter
T1
                         455kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L8
                         520kHz
CT4
                      1,680kHz
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
                         600kHz
CT3
                      1,400kHz
LW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L4
                         145kHz
CT10
                         300kHz
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L9
                         160kHz
CT9
                         260kHz
SW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L6
                         5.8MHz
CT6
                       18.4MHz
SW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L5
                         5.8MHz
CT5
                       18.4MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter
L21
                       87.0MHz
CT2
                     108.3MHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
                       87.0MHz
CT1
                     108.3MHz