– 6 –
3-1. MECHANICAL ADJUSTMENTS
PRECAUTION
1. Clean the following parts with a denatured-alcohol-moistened
swab :
record/playback head
pinch roller
erase head
rubber belts
capstan
2. Demagnetize the record/playback head with a head demagnetizer.
(Do not bring the head demagnetizer close to the erase head.)
3. Do not use a magnetized screwdriver for the adjustments.
4. After the adjustments, apply suitable locking compound to the
parts adjusted.
5. The adjustments should be performed with the rated power sup-
ply voltage unless otherwise noted.
1. Torque Measurement
Mode
Torque Meter
Meter Reading
Playback
CQ-102C
30 – 70 g • cm
(0.42–0.97 oz• inch)
Back Tension
CQ-102C
1.5 – 5.5 g • cm
(0.021–0.076 oz• inch)
Rewind
CQ-201B
55 – 135 g • cm
Fast Forward
(0.77–1.87 oz• inch)
2. Tape Tension Measurement
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 100g (3.53 oz)
SECTION 3
ADJUSTMENTS
3-2. ELECTRICAL ADJUSTMENTS
 TAPE SECTION
1. The adjustments should be performed in the order given in the
service manual. (As a general rule, playback circuit adjustment
should be completed before performing recording circuit adjust-
ment.)
2. The adjustments should be performed for both L-CH and R-CH
unless otherwise indicated.
r
Switch location
FUNCTION switch
• • • • • • • • • • • • • • • • 
TAPE (RADIO OFF)
GRAPHIC EQUALIZER
• • • • • • • • • 
center click
BALANCE
• • • • • • • • • • • • • • • • • • • • • • • • • 
center click
VOLUME
• • • • • • • • • • • • • • • • • • • • • • • • • • • 
mechanical center
BASS BOOST
• • • • • • • • • • • • • • • • • • • • • 
mechanical center
 0dB=0.775V
Tast tape
Type
Signal
Used for
WS-48B
3kHz, 0dB
Tape Speed Adjustment
P-4-A063
6.3kHz, –10dB
Azimuth Adjustment
P-4-L300
315Hz, 0dB
Level Adjustment