CFD-V17, CFD-V177 - Sony Audio Service Manual (repair manual). Page 12

Read Sony CFD-V17 / CFD-V177 Service Manual online

— 12 —
FM VCO  Adjustment
Procedure :
1. Connect frequency counter to the positions shown below.
2. Tune the set to 98MHz.
3. Adjust RV1 so that the frequency counter reading becomes
75,000 Hz.
Specification Value :
Adjustment Location : MAIN board (See page 13)
RED
10.70MHz
BLUE
10.67MHz
ORANGE
10.73MHz
BLACK
10.64MHz
WHITE
10.76MHz
0.01
µ
F
FM RF SSG
to ANT IN terminal
Carrier frequency : 98MHz
IF frequency : According to
the color of CF1.
Modulation : no modulation
Output level : 0.1V (100dB)
color
mark
CF1
Frequency counter
75,950 – 76,050 Hz
Frequency counter
0.01
µ
F
+
33k 
IC1 Pin 
4
IC1 Pin 
7
Page of 58