CFD-V17, CFD-V177 - Sony Audio Service Manual (repair manual). Page 11

Read Sony CFD-V17 / CFD-V177 Service Manual online

— 11 —
5-3.
TUNER SECTION
 Switch Location
VOLUME
: MAX
MEGA BASS
: OFF
PRESET SOUND MODE : OFF
BAND : AM
Signal generator
BAND : FM
Signal generator
0 dB = 1 µV
• Repeat the procedures in each adjustment several times for the
maximum level meter indication.
• The frequency coverage and tracking adjustments should be
finally done by the trimmer capacitors.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
455 kHz
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620 kHz
CT3
1,400 kHz
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
86.5 MHz
CT1
109.5 MHz
AM SECTION
FM SECTION
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520 kHz (516 kHz)
CT4
1,780 kHz (1,605 kHz)
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.5 MHz
CT2
109.5 MHz
Adjustment Location : Main board (See page 13)
Put the lead-wire
antenna close to
the set.
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
AM RF signal
generator
0.01
µ
F
FM RF signal
generator
telescopic
antenna
terminal
75kHz (100%) amplitude modulation
by 1kHz signal.
Output level : as low as possible
32
set
+
level meter
J301 (phones)
(   ): Australian
Page of 58