Read Sony CFD-V14 Service Manual online
– 9 –
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
< > : East European model only
[ ] : Italian model only
[ ] : Italian model only
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
455kHz
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz
[516kHz]
CT4
1,680kHz
[1,630kHz]
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620kHz
CT3
1,400kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
10.7MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
87.0MHz
<64.0MHz>
[87.35MHz]
CT2
108.3MHz
<109.5MHz>
[108.25MHz]
VCO Adjustment
Procedure :
1. Connect the frequency counter to 4 and 7 pin of IC 1 as
shown the figure below.
2. Turn the set to 98MHz.
3. Adjust RV1 for 75.95kHz – 76.05kHz reading frequency counter.
3. Adjust RV1 for 75.95kHz – 76.05kHz reading frequency counter.
[ MAIN BOARD] (Conductor side)
Adjustment Location : Main board (See page 10)
FM RF signal
generator
generator
Carrier frequency : 98MHz
Modulation : No modulation
Output level : 100dB
Modulation : No modulation
Output level : 100dB
µ
(100mV )
set
telescopic
antenna
terminal
0.01
µ
F
TUNER SECTION
0dB = 1
µ
V
AM Section
Function switch : AM
Volume
Volume
: MIN
FM Section
Function switch : FM
Volume
Volume
: MIN
AM RF signal
generator
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
signal.
Output level : as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
FM RF signal
generator
generator
22.5kHz frequency deviation by
400Hz signal.
Output level : as low as possible
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
antenna
terminal
0.01
µ
F
set
32
Ω
J301 (phones)
level meter
frequency counter
33k
Ω
1
µ
F
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.0MHz
<68.0MHz>
[87.35MHz]
CT1
108.3MHz
<102.0MHz>
[108.25MHz]
Adjustment Location : Main board (See page 10)
Click on the first or last page to see other CFD-V14 service manuals if exist.