Read Sony CFD-F15CP Service Manual online
16
CFD-F15CP
digital
voltmeter
voltmeter
100 k
Ω
TP (VT)
i
jack (J321)
set
32
Ω
level meter
(range: 0.5–5 V ac)
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
AM RF signal
generator
generator
TP (FM IN)
FM RF signal
generator
generator
0.01
µ
F
set
TUNER SECTION 0 dB = 1
µ
V
• AM Section
Setting:
RADIO BAND•AUTO PRESET button: MW or LW
RADIO BAND•AUTO PRESET button: MW or LW
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
deviation by 1 kHz signal
output level : as low as possible
• FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
RADIO BAND•AUTO PRESET button: FM
30% amplitude
modulation by
400 Hz signal
modulation by
400 Hz signal
• Connecting Level Meter (FM, MW)
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
1.0
± 0.5 V
5.2
± 0.6 V
Adjustment Part
<confirmation> <confirmation>
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
CT3
621 kHz
1,404 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3
± 0.3 V
3.0
± 0.2 V
Adjustment Part
<confirmation>
L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
Adjustment Location: See page 17.
• Connecting Digital Voltmeter (FM, MW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
done by the trimmer capacitors.
Click on the first or last page to see other CFD-F15CP service manuals if exist.