CFD-F10, CFD-F10L - Sony Audio Service Manual (repair manual). Page 16

Read Sony CFD-F10 / CFD-F10L Service Manual online

16
CFD-F10/F10L
digital
voltmeter
100 k
TP (VT)
i
 jack (J321)
set
32 
level meter
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (FM IN)
FM RF signal
generator
0.01 
µ
F
set
  TUNER SECTION     0 dB = 1 µV
• AM Section
Setting:
RADIO BAND•AUTO PRESET button: MW or LW
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM, MW and LW)
MW IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
1.0 ± 0.5 V
5.2 ± 0.6 V
Adjustment Part
<confirmation> <confirmation>
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
CT3
621 kHz
1,404 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.6 ± 0.3 V
5.0 ± 0.1 V
Adjustment Part
<confirmation>
L4
LW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
CT5
162 kHz
261 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.3 ± 0.3 V
3.0 ± 0.2 V
Adjustment Part
<confirmation>
L2
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
Adjustment Location: See page 17.
• Connecting Digital Voltmeter (FM, MW and LW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Page of 60
Display

Click on the first or last page to see other CFD-F10 / CFD-F10L service manuals if exist.