CFD-6 - Sony Audio Service Manual (repair manual). Page 9

Read Sony CFD-6 Service Manual online

– 9 –
Record/Playback Head Azimuth Adjustment
Procedure :
1. Mode : playback
test tape
P-4-A063
(6.3kHz, –10dB)
set
33
J302 (phones)
level meter
+
L-CH
peak
R-CH
peak
L-CH
peak
R-CH
peak
Screw
position
output
level
within
2dB
within
2 dB
screw position
2. Turn the adjustment screw for the maximum output levels. If
   these levels do not match, turn the adjustment screw until both
   of output levels match together within 2dB. 
3. Phase Check
Mode : playback
L-CH
H
V
L-CH
set
33
R-CH
R-CH
33
in phase     45
°
        90
°
       135
°
      180
°
good
wrong
screen pattern
test tape
P-4-A063
(6.3kHz, –10dB)
J302 (phones)
oscilloscope
+
+
Adjustment Location : – record / playback head –
adjustment screw
REC/PB head
 TUNER SECTION
 AM Section
Function switch
: AM
Volume
: MAX
AM RF signal
generator
30% amplitude modulation by 400Hz
signal.
Output level : as low as possible
Put the lead-wire
antenna close to 
the set.
 FM Section
Function switch
: FM
Volume
: MAX
FM RF signal
generator
22.5kHz frequency deviation by 
400Hz signal.
Output level : as low as possible
telescopic
antenna
terminal
0.01  F
µ
set
33
+
J302 (phones)
level meter
r
Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally done
by the trimmer capacitors.
no mark
: E, Central & South America model
 [        ]
: AEP, UK model
((       ))
: Italian model
 <       >
: East European model
                         AM IF ALIGNMENT
           Adjust for a maximum reading on level meter.
CFT1
455kHz
[ 455kHz]
(( 455kHz))
< 455kHz>
    AM FREQUENCY COVERAGE ADJUSTMENT
           Adjust for a maximum reading on level meter.
L4
520kHz
[520kHz]
((516kHz))
<520kHz>
CT4
1,680kHz
[1,680kHz]
((1,630kHz)) <1,680kHz>
                AM TRACKING ADJUSTMENT
          Adjust for a maximum reading on level meter.
L3
620kHz
[620kHz]
((620kHz))
<620kHz>
CT3
1,400kHz
[1,400kHz]
Page of 28