CDP-CX333ES, CDP-CX555ES - Sony Audio Service Manual (repair manual). Page 13

Read Sony CDP-CX333ES / CDP-CX555ES Service Manual online

13
[     ]
Special Aging Mode Functions
The aging mode is provided with the following convenient func-
tions
• Disc setting mode (*1)
• Selection of presence of protection function during error (*2)
• Count function of aging cycle (*3)
*1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
*2 Self protection function during errors:
Function which voluntarily corrects errors which occur dur-
ing normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low re-
producibility.
If this function is provided, and errors can be corrected by
retries, aging will be continued without stopping.
*3 Aging cycle count function:
Functions which displays the number of agings carried out on
the Fluorescent indicator tube  in numbers. One aging cycle
consists of five discs.
Aging Procedure
1. Turn ON the power of the unit. Press the 
[   OPEN/CLOSE]
and open the front cover.
2. Change the 
[COMMAND MODE]
 switch (S901) on set to 
[CD1]
.
3. Press the 
[AGING START]
 button of the remote commander
for aging mode (J-2501-123-A).
4. When the disc set mode is set, the 
[     ]
 and 
[   ]
 LEDs blink.
5. Rotate the 
[DISC/CHARACTER]
 dial. The slits (No. 60, 120,
180, 240, 300) for setting the discs will come forward. Insert
the discs into these slits. Do not set the discs in other slits.
6. Set whether the self-protection function during errors is
equipped with the unit. Press the 
[REPEAT]
 button. If “RE-
PEAT” is displayed on the fluorescent indicator tube, it means
the function is provided. If “REPEAT” is not displayed, it
means the function is not provided.
Error Display
7. Press the
· button.
8. The
· LED blinks, the aging mode is set, and aging is
started.
9. If errors occur during aging, the error number will be displayed
on the fluorescent indicator tube. (Refer to the following table
for the details of the errors.)
10. Aging will be repeated as long as no errors occur.
11. After each aging cycle, the number displayed on the fluores-
cent indicator tube will increase.
12. To release this mode, press the
1/
u
button.
Note:
As an alternative to steps 2 and 3, press the 
[GROUP 1]
 button,
[   OPEN/CLOSE]
 button, and 
[+100]
 button at the same time.
P
·
120
1DISC
CD1
AGED 10
number of agings
number of disc table
  
  
1 2 0
E 0 1
#
  
Aging cycle
number
Error code
Disc number
with error
Disc number
when aging
180
  
[     ]
[     ]
Error code
Code number
Err 01
Err 02
Err 03
Err 04
Err 05
Err 06
Err 
*
1
Err 
*
2
Err 
*
3
Err 
*
4
Err 
*
5
Err 
*
6
Err 
*
7
Name
DISC sensor check 1
DISC sensor check 2
Table operation check 1
Table operation check 2
Loading operation check 1
Loading operation check 2
BU related check 1
BU related check 2
BU related check 3
BU related check 4
BU related check 5
BU related check 6
BU related check 7
Contents
No disc in the specified slit
Disc in other slits
Table motor current over
No table sensor input
Load in timeover
Load out timeover
Access timeover
High speed search NG
Q data read error
BU operation (from focus search to until signal can be read) timeover
GFS monitor error
Focus cannot be imposed by focus search
Auto focus bias adjustment cannot be performed
The 
*
 numbers mean the following according to the state of the unit during aging
2 : From chucking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback
§
§
Page of 70