CDP-CE500 - Sony Audio Service Manual (repair manual). Page 19

Read Sony CDP-CE500 Service Manual online

CDP-CE500
CDP-CE500
19
19
SECTION  4
ELECTRICAL  CHECK
Note:
1.  CD Block is basically constructed to operate without adjustment.
2.  Use YEDS-18 disc (Part No. 3-702-101-01) unless otherwise indicat-
ed.
3.  Use an oscilloscope with more than 10 M
Ω impedance.
4.  Clean the object lens by an applicator with neutral detergent when the 
signal level is low than specifi ed value with the following checks.
5.  Check the focus bias check when optical pick-up block is replaced.
FOCUS  BIAS  CHECK
+
BD75 board
oscilloscope 
(DC range) 
CL102 (RFOUT)
CL117 (VREF)
Procedure:
1.  Connect the oscilloscope to CL102 (RFOUT) and CL117 
(VREF) on the BD75 board.
2.  Press the [
?/1
] button to turn the power on, and select CD 
function.
3.  Set disc (YEDS-18) and play it.
4. Confi rm that oscilloscope waveform is as shown in the fi gure 
below (eye pattern).
 
A good eye pattern means that the diamond shape (
◊) in the 
center of the waveform can be clearly distinguished.
VOLT/DIV: 200 mV 
TIME/DIV: 500 ns
level:
1.1 ± 0.4 Vp-p
Checking Location:
CL117 (VREF)
CL102 (RFOUT)
IC101
– BD75 Board (Conductor Side) –
MECHANISM  DECK  CHECK  MODE
For the mechanism deck check mode, two modes of disc table 
mode and loading mode are available.
In the mechanism deck check mode, the disc table turning time 
and the loading time in each section are measured and displayed.
Procedure:
Disc table mode:
Press three buttons of [x], [ENTER] and [DISC 4] simultaneously.
Loading mode:
Press three buttons of [x], [ENTER] and [DISC 5] simultaneously.
Display contents
Mode
Check command
Display
Disc table mode
(Table turning time 
measurement)
0: Right one turn
1: Left one Turn
2: Measurement end
r
L
r
5.7
5.6
5.7
3: Undefi ned
Table mode
(Loading time 
measurement)
4: Star position
5: Open → Close
6: Close → BU up
7: BU up → EX open
8: EX open → EX close
9: EX close → BU down
A: BU down → Open
FF: Measurement end
Sta
Clo
UP
Eop
ECL
don
oPn
CLo
– –.–
1.9
0
1.8
2.0
0.4
1.5
1.9
Display is changed by pressing the [DISPLAY] button.
Releasing method:
Press the [
?/1
] button to turn the power off.
Page of 52
Display