Read Sharp VC-T510HM (serv.man26) Technical Bulletin online
Sharp Electronics (UK) Limited
Originator AJ Supervisor Approval Date / / Reference V-89802
Revision
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
VCA105-007
Month of Issue:
Classification: Routine
VIDEO TECHNICAL BULLETIN
Page 1 of 1
MODELS
VCT510HM
VCA111HM
VCA113HM
VCA615HM
VCD805HM
VCT310HM
SYMPTOM When pressing the stop or eject button while in the play or record mode, the VCR
powers down.
CAUSE
The tension release lever ( item 52 ) flexes during unlacing, causing a delay in the
timing of the tension arm. The delay causes the arm to jam on the supply pole base
(item 76) which upsets the unload sequence, resulting in IC801 powering down the
video.
timing of the tension arm. The delay causes the arm to jam on the supply pole base
(item 76) which upsets the unload sequence, resulting in IC801 powering down the
video.
ACTION
Replace the tension release lever and the relay gear drive lever using the part
numbers listed below.
numbers listed below.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
33
Relay gear drive lever
MLEVF0289GEZZ
AE
52
Tension release lever
MLEVP0133GEZZ
AC
Display