VC-M315HM (serv.man7). Electrical troubleshooting guide - Sharp VCR Service Manual (repair manual). Page 2

Read Sharp VC-M315HM (serv.man7) Service Manual online

40
VC-M305HM/LM
VC-M315HM/LM
SWITC
FUNCTION
SWITC
FUNCTION
TERMINAL
Ref No.                                 Ref No.
                          VOLTAGE
S805
SET
S801
POWER
0.000V
S806
CH(+)
S802
EJECT
0.652V
S807
PAUSE
S803
MENU
1.864V
S808
REC
S804
CH(-)
2.561V
S883
NO USE
S881
PLAY
S884/S885
REW
S882
STOP
3.081V
S886/S887
FF
TP801
TEST
3.694V
-
-
TP802
CASSETTE
4.279V
-
-
-
-
5.000V
KEY-1 IN
KEY-0 IN
(Pin88 of IC701)
(Pin89 of IC701)
Is the cassette housing 
distorted?
NO
YES
YES
YES
YES
NO
YES
NO
NO
YES
NO
YES
FLOW CHART NO.8 CASSETTE CONTROL TROUBLESHOOTING(1)
A cassette tape is not take in.
NO
NO
Check start sensor cover.
Check line between start sensor 
and pin(87) of IC701.
Check line between pin(92) of 
IC701 and pin(10) of P701.
Is the supply voltage of 12V fed 
to pin(8) of P701?
Check M 12V  lines.
Check IC on mechanism.
Check line between IC on mechanism 
and loading motor.
Replace loading motor.
Is the specified voltage applied 
at the loading motor terminal 
when the cassette tape is inserted?
Does IC on mechanism output 
about 10V when the cassette 
tape in inserted?
Does pin(10) of P701 go to a 
"H" level when the cassette tape 
is inserted?
Does pin(87) of IC701 change 
from "H" to "L" level when the 
cassette tape is inserted?
Does the start sensor cover go 
to open when the cassette tape 
is inserted?
Does the key switch make good 
contact, when the cassette tape is 
inserted?
Check switch contact.
Is there the function control voltage 
inputted at the pins(88) and (89) of 
IC701, when the keys are activated?
Replace IC701.
Check peripheral circuit of pins(88) and 
(89) of IC701, and the function keys.
YES
NO
NO
YES
Key-in input is not received
FLOW CHART NO.7 INFRARED R/C TROUBLESHOOTING
No operation is possible from the infrared remote control.
Does the infrared remote control 
function?
Replace infrared remote control 
as required.
Is the supply voltage of 5V fed to 
pin(2) of RMC801.
Check AT 5V and GND lines.
Is "L" pulse sent out from pin(1) of 
the receiver when the infrared remote 
control is activated?
Replace receiver.
Check between at pin(1) of receiver 
and all the way up thru to pin(4) of 
IC701.
Replace IC701.
YES
NO
YES
NO
NO
NO
YES
A/D KEY INPUT
SPECIFICATION:-
FLOW CHART NO.6 TIMER TROUBLESHOOTING (2)
Fix or replace the cassette 
housing.
Page of 14