45
VC-M314HM
VC-MH834HM
FLOW CHART NO.16 DRUM SER
VO TROUBLESHOOTING
Drum servo does not function.
Check peripheral circuit of X701.
Is there 14.318MHz oscillation at 
pins(37) and (38) of IC701?
NO
In PB mode
YES
In REC mode
Is there drum FG signal at pin
(65) of IC701 present?
Is the V
-SYNC signal(reference) 
at pin(50) of IC701?
YES
NO
NO
Check peripheral circuit of pin
(50) of IC701, C746, C747 and 
R745.
Check drum FG signal line.
Is the head switching pulse at pin
(23) of IC701 present?
NO
See FLOW CHAR
T
 NO.15 
(HEAD SWITCHING PULSE 
TROUBLESHOOTING.)
YES
YES
Is the drum 
APC output at pin(34) 
of IC701 and drum 
AFC output at 
pin(32) of IC701 present?
NO
Replace IC701.
YES
YES
Is the drum control voltage 
applied to pin(2) of IC7002?
YES
Is pin(58) of IC701 in high 
impedance?
NO
YES
NO
Check line between pins(34) and 
(32) of IC701 and pin(29) of 
IC7002.
Does the IC7002 operate 
normally?
Replace IC701.
Replace drum motor
.
Page of 24