PZ-43MR2E (serv.man7). Adjustment procedures - Sharp TV Service Manual (repair manual). Page 2

Read Sharp PZ-43MR2E (serv.man7) Service Manual online

15
PZ-43MR2E
PZ-50MR2E
3. Entering a special mode
1
Entering the process adjustment mode
[Steps]
(1) When using the remote control unit:
Using the system cable, properly connect the Panel Unit and the AVC System, and then turn ON the
power.
After the system has started up, press the PROCESS ADJ button located on the remote control unit.
(2) When using buttons on the main unit:
Using the system cable, properly connect the Panel Unit and the AVC System.
Turn ON the power while holding down the INPUT and CH UP buttons located the Panel Unit.
[Description]
Various adjustments can be made manually.
2
Entering the inspection process mode
[Steps]
After the system has started up, press the PROCESS ADJ button located on the remote control unit.
Set the parameter SIGNAL INFO to 1 on page 6 or 7 of the PROCESS ADJUSTMENT A MODE MENU.
Subsequently, make the necessary adjustments in accordance with the above menu.
3
Procedure for setting up delivery
[Steps]
After the system has started up, press the DELIVERY SETUP button located on the remote control unit.
(Within the adjustment process, the channel settings remain unchanged.  Once you exit the process adjustment
mode, the channel settings entered in the delivery adjustment mode become valid.)
[Description]
The user’s adjustment parameters and others will be set to the default values.  The channel settings will also
be initialized.
4. Exiting a special mode
(1) Process adjustment mode: Press the PROCESS ADJ button located on the remote control unit or turn OFF the
power.
(2) Inspection process mode: Set the parameter SIGNAL INFO to 0 on page 6 or 7 of the PROCESS ADJ A MODE
MENU or turn OFF the power.
(3) Delivery setup:  After the delivery setup has been finished, the process adjustment mode is automatically
selected.  To exit the process adjustment mode, press the PROCESS ADJ button located on the remote control
unit or turn OFF the power.
5. OSD menu and parameters displayed at manual adjustment
*
The default values may slightly differ depending upon the program version to be rewritten.
*
The settings are not initialized to the default values by merely rewriting the program.  (See the paragraph for
Preparation for adjustment.)
(1) Descriptions of special buttons in process adjustment mode
Cursor UP key
: Proceeds to the previous page.
Cursor DOWN key : Returns to the next page.
VOL UP key
: Increases the adjusted value by 1.
VOL DOWN key
: Decreases the adjusted value by 1.
Cursor LEFT key : Decreases the adjusted value by 10.
Cursor RIGHT key : Increases the adjusted value by 10.
CH UP key
: Moves up the cursor.
CH DOWN key
: Moves down the cursor.
Page of 6
Display