LC-46XL1E. Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 14

Read Sharp LC-46XL1E Service Manual online

LC-46XL1E/RU, LC-52XL1E/RU
3 – 14
13. Lamp error detection
1. Function
This LCD color TV set incorporates a lamp error detection feature that automatically turns off the power for safety under abnormal lamp or lamp
circuit conditions. If by any chance anything is wrong with the lamp or lamp circuit or if the lamp error detection feature is activated for some rea-
son, the following will result.
1) The power is interrupted in about 6 seconds after it is turned on.
(The power LED on the front of the TV set turns red from green and keeps blinking in red: ON for 250 ms and OFF for 1 sec.).
2) If the above phenomenon 1) occurs 5 times consecutively, it becomes impossible to turn on the power. (The power LED remained red).
2. Measures
1) Checking with lamp error detection OFF
Enter the adjustment process mode, referring to “3. Entering and exiting the adjustment process mode.”
If there is a problem with the lamp or lamp circuit, the lamp will go out. (The power LED is green.)
Then, you can check the operation to see if the lamp and lamp circuit are in trouble.
2) Resetting the lamp error count
After the lamp and lamp circuit are found out of trouble, reset the lamp error count. If a lamp error is detected five consecutive times, the power
cannot be turned on. Using the cursor (UP/DOWN) key, move to the cursor to [L ERR RESET], Line 7 on adjustment process mode service
page 10/13. With the cursor (LEFT/RIGHT) keys, select the [L ERR RESET] value. Finally press the cursor (OK) eys to reset the value to “0”.
Table of contents of adjustment process mode Page 10/13
[ETC]
EEP CLEAR
off
EEP CLEAR B
off
STANDBYCAUSE RESET
off
AUTO INSTALLATION SW
0
OPTION
0
COUNTRY
EURO
L ERR RESET
0
L ERR STOP
0
DTV CLR
off
I2C-OFF
off
Resetting to "0"
Page of 16
Display

Click on the first or last page to see other LC-46XL1E service manuals if exist.