LC-46LE831E (serv.man15). Adjustment - Sharp TV Service Manual (repair manual). Page 10

Read Sharp LC-46LE831E (serv.man15) Service Manual online

LC-40/46LE830E, RU/831E, S
5 – 10
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• If “EXCUTE” is not executed, the content that does RESET is not reflected.
6. Setting items. (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode in setting to “FIXED_ALL” and “FIXED_BODYKEY”, the caution is displayed for 5 seconds.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
2) Instantaneous current shutdown setting in turning off the power [SHUT DOWN MODE]
3) Volume maximum level [MAXIMUM VOLUME]
Option
“VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RCRESPOND” (loop enabled)
Default “VARIABLE”
Function • VARIABLE
• FIXED_ALL
• FIXED_BODYKEY 
• RC RESPOND 
: “POWER/RECEPTION” key on TV unit or remote control is enabled.
: “POWER/RECEPTION” key on TV unit or remote control is disabled.
: Only the “MAIN POWER” key on TV unit is disabled (The remote control is enabled).
: The main unit’s POWER switch toggles between ON and Standby (the same operation by the 
  remote control).
Key disabled when set 
other than default
• OFF TIMER (SLEEP) (*Only when setting to FIXED_ALL)
Remarks 
• When selecting to “FIXED_ALL”, function related standby factors (see below) doesn’t work. and not selecting.
  OFF TIMER (Sleep)
  No operation OFF
  No signal OFF (including the power management)
* These items does not exist according to the model.
Option
“NORMAL” or “QUICK”
Default NORMAL
Function 
• This function decides whether scanning digital tuner is enabled or disabled when the power is standby.
     NORMAL
     QUICK
: Scanning digital tuner is enabled when the power is standby.
: Scanning digital tuner is disable.
  It is possible to put into the standby state instantaneously due to power off input, when the 
  power is standby.
  Immediately, state is a complete standby.
Remarks 
In selecting “QUICK”, the function does not work for the following items. (selection impossible.)
• ON TIMER, QUICK START, DIGITAL FIXED, etc.
* These items does not exist according to the model.
Option
0~60 (loop disabled)
Default 60
Function
The volume cannot be increased more than the adjusted value (the main unit’s speaker only).
Remarks 
• When setting to 59 or less, only the figure is displayed in the normal mode; the volume bar is not displayed.
• The volume of the headphones is limited.
• The setting is impossible when VOLUME FIXED is set to FIXED.
When power button on the main unit is pressed
When power button on R/C is pressed
No Power off by power button.
No Power off by remote control.
Page of 22