LC-46DH77E (serv.man5). Troubleshooting Table - Sharp TV Service Manual (repair manual). Page 15

Read Sharp LC-46DH77E (serv.man5) Service Manual online

LC-42DH77E/RU/S/V, LC-46DH77E/RU/S/V
4 – 15
MONITOR ERR STBY table
LED flashing timing chart at the time of the error
1) Power LED
Outline:
Communication/Power failure detected by the monitor microprocessor (IC2003) is stored on EEPROM, and the last 4 abnormal 
states can be confirmed in the adjustment process mode.
Location:
Page 1/16 of the adjustment process mode: MONITOR ERR CAUSE
“0” if there is no error. It is cleared to 0 on the last page of the adjustment process mode.
Display
Error description
02
Start-up communication error 2
Initial communication from the main CPU is not received.
03
Start-up communication error 3
Only the initial communication is received.
04
Start-up communication error 4
Until panel information request reception
05
Start-up communication error 5
Until initialization completion reception
06
Start-up communication error 6
Until version notification transmission
07
Start-up communication error 7
Until start-up information notification transmission
08
Start-up communication error 8
Until start-up information response reception
09
Start-up communication error 9
Until time-out setting reception
0A
Communication error A
REQ time-out
0B
Communication error B
Restart time-out during the beginning of time acquisition start-up
0C
Communication error C
Ending sequence time-out
0D
Communication error D
Preset start-up time-out during completion
0E
Communication error E
Download start-up time-out
0F
Communication error F
Time acquisition time-out
11
Communication error H
Regular communication time-out
16
Panel-related error
Lamp failure
1A
Other error 2
Monitor temperature failure
1D
Power supply error 1
PS_ON(AC_DET) failure
1E
Power supply error 2
D_POW(DET_12V) failure
1F
Power supply error 3
D_POW(DET_D3V3) failure
21
Power supply error 5
Panel power failure
23
Other error 3
Error standby request from the main CPU
Error type
Power LED operation (1 cycle)
Note: Pins are monitor microprocessor pins (IC2003).
Inverter/Lamp fail-
ure
Red flashes once
H: Red on
Refer to “Inverter/Lamp failure details”. OPC_LED flashes by pressing the 
[MENU] key on the remote control.
L: Off
Power failure
Red flashes twice
H: Red on
Refer to “Power failure details”. OPC_LED flashes by pressing the [MENU] 
key on the remote control.
L: Off
Communication 
failure with main 
CPU
Green flashes 
once
H: Green on
Refer to “Communication failure details”. OPC_LED flashes by pressing the 
[MENU] key on the remote control.
Communication line failure or main CPU communication failure.
L: Off
Others
Green flashes 
twice
H: Green on
Refer to “Other failure details”. OPC_LED flashes by pressing the [MENU] 
key on the remote control.
L: Off
300m
s
1.5sec
Page of 17
Display