LC-46DH77E (serv.man5). Troubleshooting Table - Sharp TV Service Manual (repair manual). Page 14

Read Sharp LC-46DH77E (serv.man5) Service Manual online

LC-42DH77E/RU/S/V, LC-46DH77E/RU/S/V
4 – 14
[2] LED flashing specification at the time of the error
Display method
• Refer to Table 1.
• Make the OPC LED flash using the [MENU] key on the remote control since the display for service persons is identified by the number of flashings
(once to 5 times).
Even if the [MENU] key is pressed again, it does not return to the display for customers (only the power LED flashes).
• After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the adjustment process screen.
LED flashing method
• Synchronize the phases of the power LED and OPC LED.
• If the LEDs have different number of flashings, adjust the flashing cycle to that where the LED flashes more times.
Table 1. Concrete flashing pattern
* 1: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
* 2: If the boot section is abnormal, there is no flashing (flashing disabled).
Item
For customers
For service persons
Cause
Power
OPC
Power
OPC
Inverter/Lamp system failure
Red flashes once
Off
Red flashes once
Flashes once
Lamp error
Power PWB failure (Power 
failure, etc.)
Red flashes twice
Off
Red flashes twice
Flashes once
AC_DET error
Flashes twice
UR+13.5V error
Flashes 3 times
D3.3V error
Flashes 5 times
Panel power supply error
Main PWB failure
Green flashes once
Off
Green flashes once
Flashes once
Initial communication error
(Communication failure, etc.)
Flashes twice
Start-up confirmation commu-
nication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Others
Green flashes twice
Off
Green flashes twice
Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times
Notification from the main 
microprocessor (*1)
VerUP executing
Orange flashes once
Off
Orange flashes once Off
Version upgrading
VerUP succeeded
Power green/OPC flash alternately
Power green/OPC flash alternately
Version upgrade succeeded
VerUP failed
Green/Red flash 
alternately
Off
Green/Red flash 
alternately
Off
Version upgrade failed
System
Red flashes 3 times
Off
Red flashes 3 times
Off
Mounting discrimination con-
nector unplugged
ROM data failure
Green/Red flash 
alternately
Off
Green/Red flash 
alternately
Off
Start-up after failing version 
upgrade (*2)
<Flashing example for customers>
Power
<Flashing example for service persons>
Power
OPC
(Displayed by the
specific operation)
300ms
300ms
1500ms
300ms
1500ms
300ms
Page of 17
Display

Click on the first or last page to see other LC-46DH77E (serv.man5) service manuals if exist.