LC-40LU700E (serv.man9). Troubleshooting Table - Sharp TV Service Manual (repair manual). Page 19

Read Sharp LC-40LU700E (serv.man9) Service Manual online

LC-32/40/46LE700E/RU/S,LU700E/S,LX700E/RU,LC-52LE700E/RU/S
6 – 19
[2] LED flashing specification at the time of the error
Display method
• Refer to Table 1.
• Make the OPC LED flash using the [MENU] key on the remote control since the display for service persons is identified by the number of flashings
(once to 5 times).
Even if the [MENU] key is pressed again, it does not return to the display for customers (only the power LED flashes).
• After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the adjustment process screen.
LED flashing method
• Synchronize the phases of the power LED and OPC LED.
• If the LEDs have different number of flashings, adjust the flashing cycle to that where the LED flashes more times.
Table 1. Concrete flashing pattern
* 1: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
* 2: If the boot section is abnormal, there is no flashing (flashing disabled).
Method of boot-up TV disregarding Error
1. Unplug the AC power cord of running TV set to force off the power.
2. While holding down the “VOL (+)” and “P (
)” keys on the set at once, plug in the AC power cord to turn on the power.
If you fail to boot-up TV, retry the procedure.
<Flashing example for customers>
Power
<Flashing example for service persons>
Power
OPC
(Displayed by the 
specific operation)
Item
For customers
For service persons
Cause
Power
OPC
Power
OPC
Inverter/Lamp system failure  Red flashes once 
Off 
Red flashes once 
Flashes once 
Lamp error
Power PWB failure (Power
Red flashes once 
Off 
Red flashes once 
Flashes once 
AC_DET error
failure, etc.)
Flashes twice 
UR+13.5V error
Flashes 3 times 
D3.3V error
Flashes 5 times 
Panel power supply error
Main PWB failure 
Green flashes once 
Off 
Green flashes once 
Flashes once 
Initial communication error
(Communication failure, etc.) 
Flashes twice 
Start-up confirmation 
communication error
Flashes 3 times 
Regular communication error
Flashes 5 times 
Other communication error
Others 
Green flashes twice 
Off 
Green flashes twice
 Flashes once 
Temperature error
Flashes twice 
Sync error
Flashes 3 times 
Notification from the main
microprocessor (*1)
VerUP executing 
Orange flashes once  Off 
Orange flashes once  Off 
Version upgrading
VerUP succeeded 
Power green/OPC flash alternately  Power green/OPC flash alternately 
Version upgrade succeeded
VerUP failed 
Green/Red flash
Off 
Green/Red flash
Off 
Version upgrade failed
alternately
alternately
System 
Red flashes 3 times
Off 
Red flashes 3 times 
Off 
Mounting discrimination 
connector unplugged
ROM data failure 
Green/Red flash
Off 
Green/Red flash
Start-up after failing version
alternately
alternately
upgrade (*2)
300ms
300ms
1500ms
300ms
300ms
1500ms
Page of 21