6 – 17
<During external connection> No picture on the monitor (3) 
                                            
No picture from EXT1 appears on EXT2-connected monitor. 
Is CVBS signal output into pin (19) of EXT2 (SC502)?
YES
Check the setting of an external input device that connects with 
EXT2.
NO
Is CVBS signal input to pin(1) of IC508 from pin(AJ24/
CVBS_MONI_OUT) of IC3302 
(Digital AV decode & Main CPU)? 
YES
Check the IC508 and their peripheral circuits.
NO
Is CVBS signal sent to pin(AG29/SC1_CVBS/Y) of IC3302
 (Digital AV decode & Main CPU) from EXT1(SC503)? 
YES
Check the IC3302 and their peripheral circuits.
NO
Is CVBS signal sent to pin (20) of EXT1(SC503)? 
YES
Check the line between EXT1(SC503) and IC3302.
NO
Check the setting of an external input device that connects with 
EXT1.
<During external connection> No picture on the monitor (4) 
                                            
No picture from EXT8 appears on EXT2- connected monitor. 
Is CVBS signal output into pin(19) of EXT2 (SC502)?
YES
Check the setting of an external input device that connects with 
EXT2.
NO
Is CVBS signal input to pin(1) of IC508 from pin(AJ24/
CVBS_MONI_OUT) of IC3302 
(Digital AV decode & Main CPU)? 
YES
Check the IC508 and their peripheral circuits.
NO
Is CVBS signal input to pin (AE29/CVBS__IN) of IC3302 from 
J505? 
YES
Check the IC3302 and their peripheral circuits.
NO
Is CVBS signal sent to pin (6) of EXT8(J505)? 
YES
Check the line between EXT8(J505) and IC3302.
NO
Is V3_PLUG detection signal input to pin (AJ11/CVBS/PLUG) of 
IC3302 from pin(7) of EXT8 (J505)? 
YES
Check the line between EXT8(J505) and IC3302.
NO
Check the setting of an external input device that connects with 
EXT8.