LC-39LE751EK. Technical Training Notes - Sharp TV Handy Guide. Page 112

Read Sharp LC-39LE751EK Handy Guide online

Issued by: 
CE After Sales Service 
Service Mode 
October 2013 
RS232 
ADJUSTMENTS….cont 
 
How 
to Change Model in “K MODE”. 
After replacing the Main Unit, check the Model Name in the following procedure. 
 
Send 
“KRCT1” to change to LE75x model. 
 
Send 
“KRCT2” to change to LE65x model. 
Confirm that OSD indicates the right MODEL after sending the command. 
 
How 
to Change Size in “K MODE”. 
After replacing the Main Unit, check the Size in the following procedure. 
 
Send 
“KPSZ392” to change to 39 inches model. 
 
Send 
“KPSZ502” to change to 50 inches model. 
Confirm that OSD indicates the right SIZE after sending the command. 
 
How 
to Adjust VCOM in “K MODE” (ONLY for 60 inches model). 
After replacing the LCD panel or LCD control PWB, adjust the VCOM in the following procedure. 
 
Place the colorimeter probe at center of the screen and set the FLICKER measurement mode on it. 
 
Activate the VCOM pattern using VCPT0001 command. 
 
Set 
the initial value of VCOM as 090 with command “VCMW1090”. 
 
Read the flicker value on colorimeter. 
 
Set other values of VCOM trying to minimize it. 
 
Please 
use the “VCMW1XXX” command to set different values (where XXX are digits 0 to 9). Generally values around 090 are the best ones. 
 
To 
hide the VCOM pattern and close the adjustment procedure please uses “VCPT0000” command. 
Page of 114
Display

Click on the first or last page to see other LC-39LE751EK service manuals if exist.