LC-37GA5E (serv.man5). Software Updating - Sharp TV Service Manual (repair manual). Page 4

Read Sharp LC-37GA5E (serv.man5) Service Manual online

24
 LC-26GA5E
 LC-32GA5E
    LC-37GA5E
- Select Bootloader option. Set AutoRead to ON and wait until 21 appears in Bootlader Version field.
- Click on the button Erase 16bit Flash. The bootloader version will be zero during few seconds. When the
  version field marks again 21 set Auto Read OFF.
- Click on the button LOAD BIN -> FLASH and the updating will start up.
- The updating will end before the progress bar reaches the end; if there is no error message the updating has
  been good.
Sometime the progress bar is very quick or error message appears, then is necessary increase the delay until
the problem disappear:
-Select LPT Preference.
 6HOHFW/373UHIHUHQFH
- Increase Delay: normally 2 or 3 are the best choice.
\
\
If there are further problems to enter the bootloader mode you can use the hardware method:
-  Power off VCTi or hold RESET line to GND.
-  Pull down SCL line to GND.
-  Power up VCTi or release RESET line.
-  Release SCL pull down after minimum of 1 second.
-  Check if VCTi is in bootloader mode with a AutoRead.