Read Sharp LC-32XL8E (serv.man3) Service Manual online
LC-32XL8E/S/RU, LC-37XL8E/S/RU
3 – 7
4. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• If not executed, the reset contents are not reflected.
• If “EXCUTE” is not executed, the content that does RESET is not reflected.
5. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode when set to “FIXED_ALL”, the caution is displayed for 5 seconds.
When power button on the main unit is pressed When power button on R/C is pressed
Option
“VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RC RESPOND” (loop enabled)
Default
“VARIABLE”
Function
• When set to “FIXED_ALL”, the “POWER/RECEPTION” key on the main unit or remote control is disabled.
However, the power can be turned off using the “MAIN POWER” switch.
• For some models, the (MAIN) POWER switch is also disabled.
• When set to “FIXED_BODYKEY”, only the “MAIN POWER” key on the main unit is disabled (the remote control is
• When set to “FIXED_BODYKEY”, only the “MAIN POWER” key on the main unit is disabled (the remote control is
enabled).
• When selecting “RC RESPOND”, the main unit’s POWER switch toggles between ON and Standby (the same
operation as the remote control).
Key disabled when set
other than default
other than default
• OFF TIMER (SLEEP)
Remarks
When selecting to “FIXED_ALL”, it functions with the correspondence which isn’t done about other standby factors
(see below).
• No operation OFF
• No signal OFF (including the power management)
(see below).
• No operation OFF
• No signal OFF (including the power management)
Public Mode
POWER ON FIXED
[VARIABLE]
SHUT DOWN MODE
[NORMAL]
MAXIMUM VOLUME
[60]
VOLUME FIXED
[VARIABLE]
VOLUME FIXED LEVEL
[20]
RC BUTTON
[RESPOND]
PANEL BUTTON
[RESPOND]
MENU BUTTON
[RESPOND]
AV POSITION FIXED
[VARIABLE]
ON SCREEN DISPLAY
[YES]
INPUT MODE START
[NORMAL]
INPUT MODE FIXED
[VARIABLE]
LOUD SPEAKER
[ON]
RC PATH THROUGH
[OFF]
232C POWON
[DISABLE]
HOTELMODE
[ON]
RESET
EXECUTE
No Power off by power button.
No Power off by remote control.
Click on the first or last page to see other LC-32XL8E (serv.man3) service manuals if exist.