8. Public Mode (Hotel Mode)
1. Starting the Public Mode
• There are two following ways to display the PUBLIC Mode setting screen.
1) On the process adjustment mode screen (2/14), set the ”HOTEL MODE” Flag to ON.
Turn off the power, and turn it on again, pressing the 
 and 
 keys of the main unit at the same time.
2) Enter the Pass Word, and start the unit.
a) Turn on the power, pressing the 
 and 
 keys of the main unit at the same time.
b) Display the Pass Word input screen.
Operation procedure
• The initial input position is the digit at the left end.
• For the numeric keys 
 to 
 of R/C, key input is accepted. Input of the other keys is prohibited.
• Change “-” to “*” by inputting the numeric key at the input position, and shift the input position rightward one digit.
• When three digits are completely input, the Pass Word is judged.
c) Check the Pass Word by inputting three digits.
If the Pass Word is 
, it shifts to the PUBLIC Mode setting screen.
In another case, the screen is erased, and it operates in the ordinary mode.
2. Exiting the Public Mode screen
• There are two following ways to exit the Public Mode setting screen.
1) Turn off the power.
2) Select “Execution” in the PUBLIC_Mode to execute it.
Activate the restart under the set content. Here, the START input SOURCE setting is excluded since this item is referred to only when the
power is turned on.
• Each set value in Public Mode is initialized when resetting to factory settings.
(The setting of the Public Mode in the process mode is also initialized.)
In Addition, industry initialization for initializing items other than each set value in Public Mode is established in the process mode.
[INDUSTRY INIT(-HOTEL)]
• Each setting is valid only when HOTLE MODE is set to ON.
• To reflect each set value, perform AC OFF/ON after determination by executing.
Set value of the Public Mode
3. Basic operation in the Public Mode
Volume (+/–) or Cursor (
/
)
Change or execution of the set value.
Channel (
/
) or Cursor (
/
)
Movement to the selected item.
Decision (ok)
Execution (Used by the items “Execution” and “RESET”.) 
PUBLIC Mode R/C
Ordinary operation mode: It enters the PUBLIC Mode.
PUBLIC MODE Flag is set to “ON”.
PUBLIC Mode: It exits the PUBLIC Mode.
PUBLIC MODE Flag does not change.
Any set item in PUBLIC Mode is not initialized.
CHANNEL UP
Volume UP
INPUT
Volume UP
0
9
0
2
7
Page of 15