6. Check the connection between TV set and PC, sending a wrong command, as for example: “aaa”. TV set returns 
an “err” label as an syntaxes ERROR (Not correct order or sequence). 
Send a “DWMD” (capital letters) command to enter TV set in Download Mode.
Change a baud rate to 115200. 
Select: 
Setup ⇒ Baud rate ⇒ 115200 ⇒ O.K.
5. Select follows settings:
Serial port to use: COM x
Baud rate:  
 9600
Data:  
 
 8 bits
Parity:    
 none
Stop:  
 
 1 bit
Flow control:  
 none
Enter O.K.
7. Select:  
File ⇒ Transfer ⇒ XMODEM ⇒ Sent