LC-32P50E. Version 1.1 - Sharp TV Handy Guide. Page 38

Read Sharp LC-32P50E Handy Guide online

Electrical Adjustments
Version 1.1
Issue 06/2006
38
SHARP ELECTRONICS (UK) LTD
CE TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
6) Display the current adjustment status at point 1. (Press the ”1” button on the remote control
to toggle between normal display and adjustment status display [normal display - ”1” -
adjustment status display - ”1” - normal display - ...].)
7) Check the brightness values using the luminance meter.
8) Change M GAMMA R1 and M GAMMA B1 on page 10/12 of process adjustment so that
the brightness becomes closest to x=0.272 and y=0.277.
9) Repeat step 6) to check the values. Repeat the steps until the brightness becomes closest
to x=0.272 and y=0.277.
10) Repeat steps 6) - 9) for points 2, 3, 4 and 5.
[W/B adjustment reference value]
Point 1 - 6 reference value x=0.272 y=0.277
Initialisation to factory settings
Caution: When the factory settings have been made, all user setting data, including the
channel settings, are initialised. (The adjustments done in the adjustment process
mode are not initialised.) Keep this in mind when initialising these settings.
Enter the adjustment process mode.
• 
Bring the cursor on to [INDUSTRY INIT] on page 2/12.
• 
Use the [Volume +-] key to select a region from [AUTO/EURO/UK/ITALY/
FRANCE/RUSSIA] and press [ENTER]. “////////” appears and initialisation starts. After a
while, “SUCCESS—[regional code]” appears and the setting is complete.
Note: Never turn the power off during initialisation.
The background appears green when succeeded, and red when failed.
* Never turn off the power during the initialisation process.
The following settings will be back to their factory ones.
1. User settings
2. Channel data (e.g. broadcast frequencies)
3. Password data
After adjustments, exit the adjustment process mode.
To exit the adjustment process mode, unplug the AC power cord from the outlet to forcibly
turn off the power.
When the power is turned off with the remote control, unplug the AC power cord and plug it
back in (wait approximately 10 seconds before plugging in the AC power cord).
Page of 47
Display