Read Sharp LC-32GD1E (serv.man7) Service Manual online
18
LC-32GD1E
LC-37GD1E
LC-37GD1E
6. Adjustment
6-1. COM BIAS adjustment
6-1. COM BIAS adjustment
Shift to the “COM BIAS” item with the cursor
'
/
"
key and select a numeric value with the cursor
Û
/
û
key.
Changing the numeric value with the cursor
'
/
"
key will make appear the test pattern. Make an adjustment
so that the flicker near the center of the screen is minimized.
Adjust each of the ones, tens and hundreds places so that the flicker is minimized.
Adjust each of the ones, tens and hundreds places so that the flicker is minimized.
6-2. White balance adjustment
The way to enter the adjustment process mode is different. Please refer to the description given for the AVC
unit.
unit.
7. Adjusting procedure by use of RS-232C
• Get ready the PC with COM port (RS-232C) running on Windows 98/98SE/ME/2000/XP operating system,
as well as the RS-232C cross cable.
• Start the unit with the RS-232C cable connected.
• Start the terminal software.
(The freeware readily available on the Internet will do.)
• Make the following settings.
as well as the RS-232C cross cable.
• Start the unit with the RS-232C cable connected.
• Start the terminal software.
(The freeware readily available on the Internet will do.)
• Make the following settings.
Baud rate
9600
Data
8 bits
Parity
None
Stop bit
1 bit
Flow control Not implemented
• If the settings are correct, the terminal software indicates “ERR” against pressing of the “ENTER” key.
• After the settings are done correctly, it is possible to make an adjustment by typing in the command shown in
the table below and pressing the “ENTER” key on the keyboard.
Command entry is successful if the terminal software indicates “OK” when the “ENTER” is pressed.
If “ERR” is shown, retry to enter the command.
• After the settings are done correctly, it is possible to make an adjustment by typing in the command shown in
the table below and pressing the “ENTER” key on the keyboard.
Command entry is successful if the terminal software indicates “OK” when the “ENTER” is pressed.
If “ERR” is shown, retry to enter the command.
8. RS232C command table
Command
Function
Remarks
MSET1001
Starting the white balance adjustment
Ending the adjustment with a numeric value other than 1001
MOFR
∗ ∗ ∗ ∗
Adjusting the R GAMMA L value
Range: 0000~0255
MOFG
∗ ∗ ∗ ∗
Adjusting the G GAMMA L value
Range: 0000~0255
MOFB
∗ ∗ ∗ ∗
Adjusting the B GAMMA L value
Range: 0000~0255
MGAR
∗ ∗ ∗ ∗
Adjusting the R GAMMA H value
Range: 0000~0255
MGAG
∗ ∗ ∗ ∗
Adjusting the G GAMMA H value
Range: 0000~0255
MGAB
∗ ∗ ∗ ∗
Adjusting the B GAMMA H value
Range: 0000~0255
MINF0000
Displaying the R GAMMA table
MINF0001
Displaying the G GAMMA table
MINF0002
Displaying the B GAMMA table
table of contents of process mode page 0
Adjust each of the ones, tens and
hundreds places so that the flicker
is minimized.
hundreds places so that the flicker
is minimized.
SERVICE S
→
GRAYLEVEL
COMBIAS
VLSBIAS
L ERR RESET
LCD
PATTERN
MOTOR AND FAN
OTHER
VER M301
VLSBIAS
L ERR RESET
LCD
PATTERN
MOTOR AND FAN
OTHER
VER M301
32/37GD1E
100
155
041
0
100
155
041
0
CEEPD
Click on the first or last page to see other LC-32GD1E (serv.man7) service manuals if exist.