LC-19D1EBK (serv.man4). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 18

Read Sharp LC-19D1EBK (serv.man4) Service Manual online

LC-19D1E/S-BK/WH
3 – 18
4. Entering and exiting the adjustment process mode
1. Press the “MAIN POWER” key, and make the TV set under operation off. 
(Or, remove the AC code of the television under operation from the outlet.)
2. While holding down the “VOL (-)” and “INPUT” keys on the set at once, Press the “MAIN POWER” key on the set to turn on the power. (Or, insert
the AC power cord in the outlet to turn on the power.)
The letter “K” appears on the upper left of the screen in white.
3. Next, hold down the “VOL (-)” and “P (
)” keys on the set at the same time at once.
If the OSD screen in clause 4-2 went out, it put it in the adjustment process mode.
If you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
4. To exit the adjustment process mode after the adjustment is done,
Press “MAIN POWER” key and turn off the power supply. (Or, unplug the AC power cord to force off the power.)
(In this machine, It is possible even if it turns off power with “Standby/On” key to Remocon.)
5. Exiting to the “K” mode, press “MAIN POWER” key, turn off the power supply, and turn on power again.
5. Operation explanation of the main unit key and remote control key in adjustment process mode.
1. key operation
2. Description of Initial Page 
Page 1
Page 2
CAUTION: Use due care in handling the information described here lest the users should know how to enter the adjustment process mode. If the 
settings are tampered with in this mode, unrecoverable system damage may result.
 Remote controller key
 Main unit key
 Function
 P (
/
)
 P (
/
)
 Changing a TV Channel (TV mode only)
 VOL (+/-)
 VOL (+/-)
 Changing a selected item setting (+1/-1)
 Cursor (UP/DOWN)
 —
 Moving an item (line) by one (UP/DOWN)
 Cursor (LEFT/RIGHT)
 —
 Changing a selected item setting (+1/-1)
 —
MENU
 Moving an item (line) by one (DOWN only)
 Displaying of MENU Screen (on TV mode)
 INPUT 
 INPUT
 Input source switching (toggle switching)
(TV
→EXT1→EXT2→EXT3→EXT4→EXT5)
 RETURN
 —
 Returning to a initial page
 OK
 —
 Entering the lower layer. 
1
MODEL
C165EA
B882E E02-0
19
ERROR NO RESET
0
ON
EXT CONTROL
OFF
DTV CLEAR
OFF
SYSCON VER ROM 1.13A GAIBU-.----
M2
VER ROM 1.05A GAIBU-.----
D SOFT VER
1.09
D LOAD VER
2.8
TERMINAL
OK
PUBLIC MODE
INCH SIZE
2
I2C DATA
000000000000
I2C DATA
WAIT
SOUND
TUNER
DVP
DVP-M2
OTHERS
HOTEL POWERFIX
ON
Page of 35
Display

Click on the first or last page to see other LC-19D1EBK (serv.man4) service manuals if exist.