LC-19D1E/S-BK/WH
3 – 1
LC19D1E-BK
Service Manual
 
CHAPTER 3. 
ADJUSTMENT PROCEDURE
[1] ADJUSTMENT PROCEDURE
1. After replacement of any PWB and/or IC for repair, note the following.
When replacing the following units, be sure to prepare the new units loaded with updated software.
     
• Note that an IC into which ROM data is written is available for MAIN-UNIT servicing (see below).
2. Software Upgrade
2.1. Preparation when software of MICON is upgraded.
2.1.1 
1. Purchase Flash ROM Writer DVP-M2 (M3A-2930) for the MAIN microcomputer from RENESAS.
2. Purchase Emulator Debugger R8C/2A (ROE000080KCE00) for the SUB microcomputer from RENESAS. 
2.1.2 
1. Preparation for installing Flash ROM Writer (M3A-2925G01) for the MAIN microcomputer
1) Connect RC32C ROM Writer to the USB terminal of the PC via a USB cable.
2) The enclosed CD-ROM is automatically installed by plug & play function of Windows.
3) Copy all files of  RC32C holder from C drive to D drive of your PC.
RC32C Ver.0.3
4) Start “RC32C_EZ.exe” up from your PC folder. 
The wizard starts up by the plug & play function then the corresponding USB driver is automatically installed.
2. Preparation for installing E8 Emulator Debugger for the SUB microcomputer
1) Connect E8 Emulator Debugger to the USB terminal of the PC via a USB cable. 
2) The enclosed CD-ROM is automatically installed by plug & play function of Windows.
3) Access the following RENESAS site and download two of the following update packages from the latest version.
http://www.renesas.com/fmwk.jsp?cnt=/download_search_results.jsp&fp=/support/downloads/download_results&layerId=1612
a) E8 Emulator Software V.2.10 Release 00 for M16C, H8 Upgrade (Full package)
Issue date:2007-8-22 48.3M
b) High-performance Embedded Workshop V.4.02.00 Differential Update
Issue date:2007-07-05 52.5M
4) Install two of the above-mentioned programs.
MAIN-UNIT: DUNTKE683FM07
IC403
RH-IXC345WJQZY
EDID (HDMI)
IC401
RH-IXC344WJQZY
EDID (PC)
LC-19D1E/S-BK/WH
3 – 2
2.2. How to connect Writer when upgrading MAIN/SUB MICON.
1. How to connect a tool for MAIN MICON
Remove a cover above the EXT5 of the TV’s rear cabinet and connect 20P connector of I/O tool.
Connect a 20P connector of RC32C ROM writer to a I/O tool.
Connect the enclosed USB cable to the USB I/F terminal of RC32C Writer.
Connect the enclosed USB cable to the USB terminal of your PC.
2. How to connect a tool for SUB MICON
Remove a cover above the EXT5 of the TV's rear cabinet and connect 20P connector of I/O tool.
Connect a 20P connector of E8 Emulator Debugger to a I/O tool.
Connect the enclosed USB cable to the USB I/F terminal of E8 Emulator Debugger.
Connect the enclosed USB cable to the USB terminal of your PC.
3. Upgrading of each microprocessor software
3.1. Sub microprocessor software version upgrade
1. Install “E8 Emulator Debugger” in CD-ROM.
2. access http://www.renesas.com/fmwk.jsp?cnt=/download_search_results.jsp&fp=/support/downloads/download_results&layerId=1612 to down-
load following two update packages:
1) E8 Emulator Software V.2.09 Release 02 for M16C, H8 Upgrade (Debugger package version)
Issue date: 2007-2-22 48.3M
2) High-performance Embedded Workshop V.4.02.00 Upgrade
Issue date:2006-12-10 52.5M
Install these packages.
3. connect E8 Emulator Debugger to PC from USB port. (drivers at folder “E8 Emulator Debugger”)
4. connect E8 writer to LCD’s 20PIN port which near EXT5 terminal, use convertor1.
5. run “High Performance Embedded Workshop” in start menu.
1
2
3
4
TV
RC32C ROM Writer (M3A-2925G01)
Personal computer
I/O tool
KSETNA001WJZZ
Parts Code
20P
Parts Code
QCNW-G882WJQZ
USB Cable
20P
USB
TERMINAL
1
2
3
4
TV
E8 Emurator Debugger
Personal computer
I/O tool
Parts Code
QCNW-G882WJQZ
Parts Code
KSETNA002WJZZ
USB Cable
20P
USB
TERMINAL
LC-19D1E/S-BK/WH
3 – 3
6. Choose “Create a new project workspace”.
7. Select “CPU family: M16C and Tool chain: None”.
LC-19D1E/S-BK/WH
3 – 4
8. Selects “R8C E8 system”.
9. Press “Complete”. 
Page of 35
Display

Download Sharp LC-19D1EBK (serv.man4) Service Manual (Repair Manual)

Here you can read online and download Sharp LC-19D1EBK (serv.man4) Service Manual in PDF. LC-19D1EBK (serv.man4) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sharp LC-19D1EBK (serv.man4) LCD. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.