76DW-18H (serv.man2). Fault finding guide - Sharp TV Service Manual (repair manual). Page 13

Read Sharp 76DW-18H (serv.man2) Service Manual online

Sharp Electronics (UK) Limited
Originator AvW   Supervisor                        Approval Date    /   /     Reference SP84001X
Revision 2
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
CTV990107
Month of Issue:    January 1999
        Classification:                   White
TELEVISION TECHNICAL BULLETIN
Page 3 of 3
 PHILIPS CRT  Original deflection yoke PWB shown on left
                              CONNE                           
Connector 1
                            Orange    Yellow       Green                                                             Yellow       Green
                Red                                                                                             Red  Orange
To change the deflection yoke wiring from a Thomson CRT to a Philips CRT, proceed as
follows
1.  Unsolder both the green and yellow (FV) and red and orange (FH) leads from the
deflection yoke PWB.
2.  Solder these leads to the Philips CRT as shown above.
3.  Replace wire KC (QCNW-2775BMZZ) that connects from the CRT socket PWB to the
neck of the CRT with lead QCNW-2757BMZZ.
KC lead
 
Sharp Electronics (UK) Limited 
Reference JR031299-1
   
Revision  2 
 
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units   
CTV991202 
Month of Issue: December 1999 
        Classification:                   White   
TELEVISION TECHNICAL BULLETIN 
 
 
 
 
 
Page 1 of 1 
 
 
MODELS
 
 
66DW18H 
76DW18H 
76EF19H 
76EF20H 
 
 
 
 
 
 
SYMPTOM  
The following problems can occur on the 100Hz PWB. 
 
• 
Intermittent digital noise on the picture  
• 
Intermittent mosaic squares on the picture  
• 
Mosaic effect if the 100Hz PWB is tapped  
• 
Red, green or blue screen if the 100Hz PWB is tapped        
 
 
 
CAUSE 
Problems around the field mixer IC, SDA9270. 
 
• 
IC6108 in the 66DW18H and 76DW18H 
• 
IC6105 in the 76EF19H and 76EF20H       
 
 
ACTION 
Carry out the following counter measures.  
 
1.  Make sure that there are no dry joints on the Mother PWB  
2.  Resolder  IC6108/IC6105  by  reflowing  the  device  -  it  is  not  necessary  to  remove 
IC6108/IC6105   
 
Note that you can operate the 100Hz PWB with the shield cans removed.   
 
It  is  important  that  these  are  returned  to  there  original  condition  when  the  job  is 
completed.            
 
 
Page of 13
Display

Download Sharp 76DW-18H (serv.man2) Service Manual (Repair Manual)