76DW-18H (serv.man37). Counter measure for loss of colour or sync while in the NTSC mode - Sharp TV Technical Bulletin (repair manual)

76dw-18h (serv.man37) technical bulletin
Model
76DW-18H (serv.man37)
Pages
1 Few pages! See other manuals at the bottom of the first or last page.
Size
7.94 KB
Type
PDF
Document
Technical Bulletin
Brand
Device
TV / CTR / Counter measure for loss of colour or sync while in the NTSC mode
File
76dw-18h-sm37.pdf
Date

Read Sharp 76DW-18H (serv.man37) Technical Bulletin online

Sharp Electronics (UK) Limited
Originator AvW   Supervisor                        Approval Date    /   /     Reference GE84300X
Revision  2
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
CTV990104
Month of Issue: January 1999
        Classification:                White
TELEVISION TECHNICAL BULLETIN
Page 1 of 1
MODELS
66DW18H
76DW18H
SYMPTOM While in the NTSC mode, colour or sync may be lost.
CAUSE
Corruption of the EPROM data.
ACTION
Change the EPROM, using the part number given below.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
IC1004
EPROM, 66DW18H
CH-IX1642CJH0
AZ
IC1004
EPROM, 76DW18H
CH-IX1642CJH1
AX
Display

Download Sharp 76DW-18H (serv.man37) Technical Bulletin

Here you can read online and download Sharp 76DW-18H (serv.man37) Technical Bulletin in PDF. 76DW-18H (serv.man37) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp 76DW-18H (serv.man37) CTR. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.